We will make full use of our professional skills to improve the quality of our 4mm 3 core nyy-j cable black, PTFE Wrapping Wire, Shielded Cat6 Patch Cord and technology. Our company constantly strive to make marketing become a tool to help us realize our own value multiplication. We further strengthen our market awareness, become more responsive to the market, and further improve our ability to cope with the market. With the development of Internet, our company deals with the internal affairs of the enterprise through the Internet, improves the efficiency and market reaction ability of the enterprise, so as to be more competitive.
Description: High Voltage XLPE Cable XLPE insulated Electric Power Cable
Hot export specification: 240mm, 300mm2, 400mm2, 630mm2
Application of High Voltage XLPE Cable
HV power cable can be used for power plant and substation.It is suitable for use in power transmission and distribution lines with rated power frequency voltage 48/66kV,64/110kV, 76/132kV
Type name of High Voltage XLPE Cable
YJLW02: corrugated aluminum inner sheath, PVC Jacket
YJLW03: corrugated aluminum inner sheath, PE Jacket
YJQ02: Lead inner sheath,PVC Jacket
YJQ03: Lead inner sheath,PE Jacket
Standard: GB/T 11017,IEC 60840
This product by GB11017 "rated voltage of 110 kV copper, Aluminum core XLPE power cable" and IEC60840 "rated voltage 30 kV to 150kV power
cable insulation crowded pack test" standard.
Using characteristics
Rated power-frequency voltage U0/U: 48/66kV,64/110kV,76/132kV.
Max. permissible continuous operating temperature of conductor: 90ºC.
Max. short-circuit temperature
of conductor shall not exceed 250ºC(5s maximum duration).
The ambient temperature under installation should not below 0ºC.
The bending radius should not less than 25 times of the cable diameter.
Application & Laying place
For laying indoors, underground laying directly buried,in tunnel, conduit, able to bear external mechanical forces and certain pulling force.
Technical Parameters:
Section area | Insulation Thickness | Metallic Sheath Thickness | Sheath Thickness | Overall Diameter | Calculated Cable Weight | Max. D.C. Conductor Resistance at 20°C |
No.x mm2 | mm | mm | mm | mm | kg/km | Ω/km |
48/66 kV | ||||||
1x185 | 14.5 | 2 | 4 | 68.3 | 5250 | 0.0991 |
1x240 | 14.5 | 2 | 4 | 76.7 | 5740 | 0.0754 |
1x300 | 14.5 | 2 | 4 | 79.1 | 6440 | 0.0601 |
1x400 | 14.5 | 2 | 4 | 82.3 | 7480 | 0.047 |
1x500 | 14.5 | 2 | 4 | 85.9 | 8750 | 0.0366 |
1x630 | 14.5 | 2 | 4 | 85.9 | 10360 | 0.0283 |
1x800 | 14.5 | 2 | 4 | 94.3 | 12260 | 0.0221 |
1x800 | 14.5 | 2 | 4 | 96.4 | 13790 | 0.0221 |
1x1000 | 14.5 | 2 | 4.5 | 102.8 | 15470 | 0.0176 |
1x1200 | 14.5 | 2 | 4.5 | 106.2 | 17580 | 0.0151 |
1x1400 | 14.5 | 2 | 5 | 110.4 | 20110 | 0.0129 |
1x1600 | 14.5 | 2 | 5 | 114.8 | 22510 | 0.0113 |
1x2000 | 14.5 | 2 | 5 | 121.8 | 27050 | 0.0009 |
64/110 kV | ||||||
1x240 | 19 | 2 | 4 | 85 | 7750 | 0.0754 |
1x300 | 18.5 | 2 | 4 | 86.1 | 8360 | 0.0601 |
1x400 | 17.5 | 2 | 4 | 86.9 | 9120 | 0.047 |
1x500 | 17 | 2 | 4 | 89.1 | 10260 | 0.0366 |
1x630 | 16.5 | 2 | 4.5 | 92.1 | 11750 | 0.0283 |
1x800 | 16 | 2 | 4.5 | 95 | 13520 | 0.0221 |
1x800 | 16 | 2 | 4.5 | 100 | 14320 | 0.0221 |
1x1000 | 16 | 2.3 | 4.5 | 105.4 | 16760 | 0.0176 |
1x1200 | 16 | 2.3 | 5 | 109.8 | 18900 | 0.0151 |
1x1400 | 16 | 2.3 | 5 | 114 | 21530 | 0.0129 |
1x1600 | 16 | 2.3 | 5 | 117.4 | 23930 | 0.0113 |
1x2000 | 16 | 2.3 | 5 | 124.4 | 27750 | 0.0009 |
127/220 kV | ||||||
1x300 | 27 | 2.4 | 5 | 112.5 | 10930 | 0.0601 |
1x400 | 27 | 2.4 | 5 | 118 | 11750 | 0.047 |
1x500 | 27 | 2.4 | 5 | 121.2 | 12880 | 0.0366 |
1x630 | 26 | 2.4 | 5 | 123 | 14320 | 0.0283 |
1x800 | 25 | 2.4 | 5 | 124.9 | 15720 | 0.0221 |
1x800 | 16 | 2 | 4.5 | 100 | 14320 | 0.0221 |
1x1000 | 24 | 2.6 | 5 | 129.4 | 20500 | 0.0176 |
1x1200 | 24 | 2.6 | 5 | 132.6 | 22810 | 0.0151 |
1x1400 | 24 | 2.6 | 5 | 136.8 | 25450 | 0.0129 |
1x1600 | 24 | 2.6 | 5 | 140.6 | 28050 | 0.0113 |
1x2000 | 24 | 2.8 | 5 | 147.5 | 32210 | 0.0009 |
Packing of High Voltage XLPE Cable:
Heat treated wooden drum, Steel Wooden drum, or Steel drum

Drawing for 110kv copper conductor xlpe insulated HV Power cable
Specifications:
1) 66KV -220kV XLPE insulated/copper or aluminum/corrugated aluminum sheathed/PVC
High Quality 66-220kV XLPE Insulated Power Cable-
66KV-220kV XLPE insulated power cable;
Construction:
Conductor : copper conductor, Or aluminum conductor
XLPE insulation, corrugated aluminum sheath, PVC / PE outer sheath,
longitudinal water-proof power cable
2) XLPE insulation, corrugated aluminum sheath, PVC / PE outer sheath,
longitudinal water-proof frame -resistant power cable
3) XLPE insulation, corrugated aluminum sheath,
PVC / PE outer sheath,
power cable
4) XLPE insulation, corrugated aluminum sheath, PVC / PE outer sheath,
fire-resistant power cable
Welcome to Visit Our Factory
Some Popular Products:
We improve the technology level through design optimization and effectively reduce the production cost of High Voltage XLPE Insulated Power Cable Promotion Price. We work hard to escort the development of the industry with scientific management methods and strong technical force. In the future, our company will always focus on customers, continuously increase investment in research and development, accelerate product iteration, increase production capacity, and continue to expand market share.
Hot Tags: high voltage XLPE cable, China, suppliers, manufacturers, factory, wholesale, price, in stock, price list, made in China, 3 Core Flexible Cord, High Voltage Cable, Single Core PVC Insulated Power Cable, single core xlpe swa cable, Cat5e Cable, single core 33kv xlpe cable