We have become a leader in the H05RN F, Transparent Speaker Cable, High Temperature Wire industry through strict management, advanced business models, practical experience, and rich customer resources. Our company has always regarded the reform and innovation of the technical department as the top priority. We expect to provide products and services to more users in global aftermarket markets; we launched our global branding strategy by providing our excellent products all over the world by virtue of our well reputed partners letting global users keep pace with technology innovation and achievements with us. We take efficiency improvement as the main line of work and actively promote the transformation of our employees.
AAAC Aaac Conductor -All Aluminum Alloy Conductor
1.Bare AAAC conductor is usually used for power transmission line project.
2.We are familiar with different international standards with IEC,BS,DIN, ASTM.We an supply very professional service for customer.
3.Packing: in drums in 2000m or 3000m according to customer’s requirement
4.Delivery: about 50km production per day
AAAC Conductor (JLHA1)
Standard: Chinese Standard GB/T 1179-2008
Nominal Aera mm2 | Code Number | Calculated Area mm2 | Number of Wires | Diameter | Rated Strength KN | Max. D.C. Resistance at 20℃ ≤Ω/km | |
Wire mm | OD mm | ||||||
20 | 16 | 18.6 | 7 | 1.84 | 5.52 | 6.04 | 1.7896 |
30 | 25 | 29.0 | 7 | 2.30 | 6.90 | 9.44 | 1.1453 |
45 | 40 | 46.5 | 7 | 2.91 | 8.72 | 15.10 | 0.7158 |
75 | 63 | 73.2 | 7 | 3.65 | 10.9 | 23.06 | 0.4545 |
120 | 100 | 116 | 19 | 2.79 | 14.0 | 37.76 | 0.2877 |
145 | 125 | 145 | 19 | 3.12 | 15.6 | 47.20 | 0.2302 |
185 | 160 | 186 | 19 | 3.53 | 17.6 | 58.56 | 0.1798 |
230 | 200 | 232 | 19 | 3.95 | 19.7 | 73.20 | 0.1439 |
300 | 250 | 290 | 19 | 4.41 | 22.1 | 91.50 | 0.1151 |
360 | 315 | 366 | 37 | 3.55 | 24.8 | 115.29 | 0.0916 |
465 | 400 | 465 | 37 | 4.00 | 28.0 | 146.40 | 0.0721 |
520 | 450 | 523 | 37 | 4.24 | 29.7 | 164.70 | 0.0641 |
580 | 500 | 581 | 37 | 4.47 | 31.3 | 183.00 | 0.0577 |
650 | 560 | 651 | 61 | 3.69 | 33.2 | 204.96 | 0.0516 |
720 | 630 | 732 | 61 | 3.91 | 35.2 | 230.58 | 0.0458 |
825 | 710 | 825 | 61 | 4.15 | 37.3 | 259.86 | 0.0407 |
930 | 800 | 930 | 61 | 4.40 | 39.6 | 292.80 | 0.0361 |
1050 | 900 | 1046 | 91 | 3.83 | 42.1 | 329.40 | 0.0321 |
1150 | 1000 | 1162 | 91 | 4.03 | 44.4 | 366.00 | 0.0289 |
1300 | 1120 | 1301 | 91 | 4.27 | 46.9 | 409.92 | 0.0258 |
AAAC Conductor
Standard: ASTM B399
Code name | Area | No./wire diameter | Overall diameter | Weight | Nominal breaking load | Standard length | |
Nominal | Actual | ||||||
MCM | mm2 | mm | mm | Kg/km | KN | m±5% | |
Akron | 30.58 | 15.48 | 7/1.68 | 5.04 | 42.7 | 4.92 | 3000 |
Alton | 48.69 | 24.71 | 7/2.12 | 6.35 | 68.0 | 7.84 | 3000 |
Ames | 77.47 | 39.22 | 7/2.67 | 8.02 | 108 | 12.45 | 2000 |
Azusa | 123.3 | 62.38 | 7/3.37 | 10.11 | 172 | 18.97 | 2000 |
Anaheim | 155.4 | 78.65 | 7/3.78 | 11.35 | 217 | 23.93 | 3000 |
Amherst | 195.7 | 99.22 | 7/4.25 | 12.75 | 273 | 30.18 | 2500 |
Alliance | 246.9 | 125.1 | 7/4.77 | 14.31 | 345 | 38.05 | 2000 |
Butte | 312.8 | 158.6 | 19/3.26 | 16.30 | 437 | 48.76 | 3000 |
Canton | 394.5 | 199.9 | 19/3.66 | 18.30 | 551 | 58.91 | 2500 |
Cairo | 465.4 | 235.8 | 19/3.98 | 19.88 | 650 | 69.48 | 2000 |
Darien | 559.5 | 283.5 | 19/4.36 | 21.79 | 781 | 83.52 | 2000 |
Elgin | 652.4 | 330.6 | 19/4.71 | 23.54 | 911 | 97.42 | 1500 |
Flint | 740.8 | 375.3 | 37/3.59 | 25.16 | 1035 | 108.21 | 3000 |
Greely | 927.2 | 469.8 | 37/4.02 | 28.14 | 1295 | 135.47 | 2500 |
AAAC conductor
Standard: ASTM B399
Area | No./wire diameter | Overall diameter | Weight | Nominal breaking load | Max D.C. resistance at 20℃ | Standard length | |
Nominal | Actual | ||||||
AWG or MCM | mm2 | mm | mm | Kg/km | KN | Ω/km | m±5% |
6 | 13.30 | 7/1.554 | 4.67 | 37 | 4.22 | 2.5199 | 3500 |
4 | 21.15 | 7/1.961 | 5.89 | 58 | 6.71 | 1.5824 | 3000 |
2 | 33.63 | 7/2.474 | 7.42 | 93 | 10.68 | 0.9942 | 2500 |
1/0 | 53.48 | 7/3.119 | 9.36 | 148 | 16.97 | 0.6256 | 2000 |
2/0 | 67.42 | 7/3.503 | 10.51 | 186 | 20.52 | 0.4959 | 3500 |
3/0 | 85.03 | 7/3.932 | 11.80 | 234 | 25.86 | 0.3939 | 3000 |
4/0 | 107.23 | 7/4.417 | 13.26 | 296 | 32.63 | 0.3119 | 2000 |
250 | 126.66 | 19/2.913 | 14.57 | 349 | 38.93 | 0.2642 | 2000 |
300 | 152.10 | 19/3.193 | 15.97 | 419 | 46.77 | 0.2199 | 3000 |
350 | 177.35 | 19/3.447 | 17.24 | 489 | 52.25 | 0.1887 | 3000 |
400 | 202.71 | 19/3.686 | 18.43 | 559 | 59.74 | 0.1650 | 2500 |
450 | 228.00 | 19/3.909 | 19.66 | 629 | 67.19 | 0.1467 | 2000 |
500 | 253.35 | 19/4.120 | 20.60 | 698 | 74.64 | 0.1321 | 2000 |
550 | 278.60 | 37/3.096 | 21.67 | 768 | 83.80 | 0.1202 | 2000 |
600 | 303.80 | 37/3.233 | 22.63 | 838 | 91.38 | 0.1102 | 2000 |
650 | 329.25 | 37/3.366 | 23.56 | 908 | 97.94 | 0.1016 | 2000 |
700 | 354.55 | 37/3.493 | 24.45 | 978 | 102.20 | 0.0944 | 3500 |
750 | 380.20 | 37/3.617 | 25.32 | 1049 | 109.60 | 0.0880 | 3000 |
800 | 405.15 | 37/3.734 | 26.14 | 1117 | 116.80 | 0.0826 | 3000 |
900 | 456.16 | 37/3.962 | 27.73 | 1258 | 131.50 | 0.0733 | 3000 |
1000 | 506.71 | 37/4.176 | 29.23 | 1399 | 146.10 | 0.0660 | 2500 |
AAAC Conductor Cable
Standard: BS EN50183
Code name | Calculated area | No of wires | Diameter | Weight | Rated strength | Max D.C. resistance at 20℃ | |
Wire | Cond | ||||||
mm2 | mm | mm | Kg/km | KN | Ω/km | ||
Box | 18.8 | 7 | 1.85 | 5.55 | 51.4 | 5.55 | 1.7480 |
Acacia | 23.8 | 7 | 2.08 | 6.24 | 64.9 | 7.02 | 1.3828 |
Almond | 30.1 | 7 | 2.34 | 7.02 | 82.2 | 8.88 | 1.0926 |
Cedar | 35.5 | 7 | 2.54 | 7.62 | 96.8 | 10.46 | 0.9273 |
Deodar | 42.2 | 7 | 2.77 | 8.31 | 115.2 | 12.44 | 0.7797 |
Fir | 47.8 | 7 | 2.95 | 8.85 | 130.6 | 14.11 | 0.6875 |
Hazel | 59.9 | 7 | 3.30 | 9.90 | 163.4 | 17.66 | 0.5494 |
Pine | 71.6 | 7 | 3.61 | 10.8 | 195.6 | 21.14 | 0.4591 |
Holly | 84.1 | 7 | 3.91 | 11.7 | 229.5 | 24.79 | 0.3913 |
Willow | 89.7 | 7 | 4.04 | 12.1 | 245.0 | 26.47 | 0.3665 |
Oak | 118.9 | 7 | 4.65 | 14.0 | 324.5 | 65.07 | 0.2767 |
Mulberry | 150.9 | 19 | 3.18 | 15.9 | 414.3 | 44.52 | 0.2192 |
Ash | 180.7 | 19 | 3.48 | 17.4 | 496.1 | 53.31 | 0.1830 |
Elm | 211.0 | 19 | 3.76 | 18.8 | 579.2 | 62.24 | 0.1568 |
Poplar | 239.4 | 37 | 2.87 | 20.1 | 659.4 | 70.61 | 0.1387 |
Sycamore | 303.2 | 37 | 3.23 | 22.6 | 835.2 | 89.40 | 0.1095 |
Upas | 362.1 | 37 | 3.53 | 24.7 | 997.5 | 106.82 | 0.0917 |
Yew | 479.0 | 37 | 4.06 | 28.4 | 1319.6 | 141.31 | 0.0693 |
Totara | 498.1 | 37 | 4.14 | 29.0 | 1372.1 | 145.93 | 0.0666 |
Rubus | 586.9 | 61 | 3.50 | 31.5 | 1622.0 | 173.13 | 0.0567 |
Sorbus | 659.4 | 61 | 3.71 | 33.4 | 1822.5 | 194.53 | 0.0505 |
Araucaria | 821.1 | 61 | 4.14 | 37.3 | 2269.4 | 242.24 | 0.0406 |
Redwood | 996.2 | 61 | 4.56 | 41.0 | 2753.2 | 293.88 | 0.0334 |
AAAC
Standard: BS 3242
Code name | Nominal area | No of wires | Diameter | Weight | Rated strength | Max D.C. resistance at 20℃ | |
Wire | Cond | ||||||
mm2 | mm | mm | Kg/km | KN | Ω/km | ||
Box | 15 | 7 | 1.85 | 5.55 | 51 | 5.37 | 1.7495 |
Acacia | 20 | 7 | 2.08 | 6.24 | 65 | 6.80 | 1.3840 |
Almond | 25 | 7 | 2.34 | 7.02 | 82 | 8.61 | 1.0934 |
Cedar | 30 | 7 | 2.54 | 7.62 | 97 | 10.14 | 0.9281 |
- | 35 | 7 | 2.77 | 8.31 | 115 | 12.05 | 0.7804 |
Fir | 40 | 7 | 2.95 | 8.85 | 131 | 13.67 | 0.6880 |
Hazel | 50 | 7 | 3.30 | 9.90 | 164 | 17.11 | 0.5498 |
Pine | 60 | 7 | 3.61 | 10.83 | 196 | 20.48 | 0.4594 |
- | 70 | 7 | 3.91 | 11.73 | 230 | 24.02 | 0.3917 |
Willow | 75 | 7 | 4.04 | 12.12 | 245 | 25.65 | 0.3669 |
- | 80 | 7 | 4.19 | 12.57 | 264 | 27.58 | 0..3441 |
- | 90 | 7 | 4.44 | 13.32 | 298 | 31.12 | 0.3023 |
Oak | 100 | 7 | 4.65 | 13.95 | 325 | 33.98 | 0.2769 |
- | 100 | 19 | 2.82 | 14.1 | 326 | 33.93 | 0.2787 |
Mulberry | 125 | 19 | 3.18 | 15.9 | 415 | 43.12 | 0.2192 |
Ash | 150 | 19 | 3.48 | 17.4 | 497 | 51.64 | 0.1831 |
Elm | 175 | 19 | 3.76 | 18.8 | 580 | 60.30 | 0.1568 |
Poplar | 200 | 37 | 2.87 | 20.09 | 659 | 88.41 | 0.1385 |
- | 225 | 37 | 3.05 | 21.35 | 744 | 77.24 | 0.1227 |
Sycamore | 250 | 37 | 3.22 | 22.54 | 835 | 86.64 | 0.1093 |
Upas | 300 | 37 | 3.53 | 24.71 | 997 | 103.50 | 0.09156 |
Walnut | 350 | 37 | 3.81 | 26.67 | 1162 | 120.53 | 0.07860 |
Yew | 400 | 37 | 4.06 | 28.42 | 1319 | 136.85 | 0.06921 |
Totara | 425 | 37 | 4.14 | 28.98 | 1372 | 142.33 | 0.06656 |
Rubus | 500 | 61 | 3.50 | 31.5 | 1620 | 167.71 | 0.05662 |
Sorbus | 659.4 | 61 | 3.71 | 33.4 | 1822.5 | 194.53 | 0.0505 |
Araucaria | 700 | 61 | 4.14 | 37.26 | 2266 | 234.50 | 0.04047 |
AAAC
Standard: DIN 48201
Code number | Calculated area | No of wires | Diameter | Weight | Rated tensile strength | Max D.C. resistance at 20℃ | |
Wire | Cond | ||||||
mm2 | mm2 | mm | mm | Kg/km | daN | Ω/km | |
16 | 15.89 | 7 | 1.70 | 5.1 | 43 | 444 | 2.0910 |
25 | 24.25 | 7 | 2.10 | 6.3 | 66 | 677 | 1.3703 |
35 | 34.36 | 7 | 2.50 | 7.5 | 94 | 960 | 0.9669 |
50 | 49.48 | 7 | 3.00 | 9.0 | 135 | 1382 | 0.6714 |
50 | 48.35 | 19 | 1.80 | 9.0 | 133 | 1350 | 0.6905 |
70 | 65.81 | 19 | 2.10 | 10.5 | 181 | 1838 | 0.5073 |
95 | 93.27 | 19 | 2.50 | 12.5 | 256 | 2605 | 0.3579 |
120 | 116.99 | 19 | 2.80 | 14.0 | 322 | 3268 | 0.2854 |
150 | 147.11 | 37 | 2.25 | 15.8 | 406 | 4109 | 0.2274 |
185 | 181.62 | 37 | 2.50 | 17.5 | 500 | 5073 | 0.1842 |
240 | 242.54 | 61 | 2.25 | 20.3 | 670 | 6774 | 0.1383 |
300 | 299.43 | 61 | 2.50 | 22.5 | 827 | 8363 | 0.1120 |
400 | 400.14 | 61 | 2.89 | 26.0 | 1104 | 11176 | 0.0838 |
500 | 499.63 | 61 | 3.23 | 29.1 | 1379 | 13960 | 0.06709 |
625 | 626.20 | 91 | 2.96 | 32.6 | 1732 | 17490 | 0.0540 |
800 | 802.09 | 91 | 3.35 | 36.9 | 2218 | 22402 | 0.0418 |
1000 | 999.71 | 91 | 3.74 | 41.1 | 2767 | 27922 | 0.0335 |
AAAC(Characteristics of A2 Conductors)
Standard: IEC 61089
Code Number | Calculated Area | Number of Wires | Diameter of Wire | Diameter of Cond. | Linear Mass | Rated Strength | Max.D.C. Resistance At 20℃ |
mm2 | mm2 | mm | mm | kg/km | kN | Ω/km | |
16 | 18.4 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 1.7896 |
25 | 28.8 | 7 | 2.29 | 6.87 | 78.7 | 8.49 | 1.1453 |
40 | 46.0 | 7 | 2.89 | 8.67 | 125.9 | 13.58 | 0.7158 |
63 | 72.5 | 7 | 3.63 | 10.8 | 198.3 | 21.39 | 0.4545 |
100 | 115 | 19 | 2.78 | 13.9 | 316.3 | 33.95 | 0.2877 |
125 | 144 | 19 | 3.10 | 15.5 | 395.4 | 42.44 | 0.2302 |
160 | 184 | 19 | 3.51 | 17.55 | 506.1 | 54.32 | 0.1798 |
200 | 230 | 19 | 3.93 | 19.65 | 632.7 | 67.91 | 0.1439 |
250 | 288 | 19 | 4.39 | 21.95 | 790.8 | 84.68 | 0.1151 |
315 | 363 | 37 | 3.53 | 24.71 | 998.9 | 106.95 | 0.0916 |
400 | 460 | 37 | 3.98 | 27.86 | 1268.4 | 135.81 | 0.0721 |
450 | 518 | 37 | 4.22 | 29.54 | 1426.9 | 152.79 | 0.0641 |
500 | 575 | 37 | 4.45 | 31.15 | 1585.5 | 169.76 | 0.0577 |
560 | 645 | 61 | 3.67 | 33.03 | 1778.4 | 190.14 | 0.0516 |
630 | 725 | 61 | 3.89 | 35.01 | 2000.7 | 213.90 | 0.0458 |
710 | 817 | 61 | 4.13 | 37.17 | 2254.8 | 241.07 | 0.0407 |
800 | 921 | 61 | 4.38 | 39.42 | 2540.6 | 271.62 | 0.0361 |
900 | 1036 | 91 | 3.81 | 41.91 | 2861.1 | 305.58 | 0.0632 |
1000 | 1151 | 91 | 4.01 | 44.11 | 3179.0 | 339.53 | 0.0289 |
1120 | 1289 | 91 | 4.25 | 46.75 | 3560.5 | 380.27 | 0.0258 |
1252 | 1439 | 91 | 4.49 | 49.39 | 3973.7 | 424.41 | 0.0231 |
AAAC(Characteristics of A3 Conductors)
Standard : IEC 61089
Code Number | Calculated Area | Number of Wires | Diameter of Wire | Diameter of Cond. | Linear Mass | Rated Strength | Max.D.C. Resistance At 20℃ |
mm2 | mm2 | mm | mm | kg/km | kN | Ω/km | |
16 | 18.6 | 7 | 1.84 | 5.52 | 50.8 | 6.04 | 1.7896 |
25 | 29.0 | 7 | 2.30 | 6.90 | 79.5 | 9.44 | 1.1453 |
40 | 46.5 | 7 | 2.91 | 8.73 | 127.1 | 15.10 | 0.7158 |
63 | 73.2 | 7 | 3.65 | 10.95 | 200.2 | 23.06 | 0.4545 |
100 | 116 | 19 | 2.79 | 13.95 | 319.3 | 37.76 | 0.2877 |
125 | 145 | 19 | 3.12 | 15.6 | 399.2 | 47.20 | 0.2302 |
160 | 186 | 19 | 3.53 | 17.65 | 511.0 | 58.56 | 0.1798 |
200 | 232 | 19 | 3.95 | 19.75 | 638.7 | 73.20 | 0.1439 |
250 | 290 | 19 | 4.41 | 22.05 | 798.4 | 91.50 | 0.1151 |
315 | 366 | 37 | 3.55 | 24.85 | 1008.4 | 115.29 | 0.0916 |
400 | 465 | 37 | 4.00 | 28.0 | 1280.5 | 146.40 | 0.0721 |
450 | 523 | 37 | 4.24 | 29.68 | 1440.5 | 164.70 | 0.0641 |
500 | 581 | 37 | 4.47 | 31.29 | 1600.6 | 183.00 | 0.0577 |
560 | 651 | 61 | 3.69 | 33.21 | 1795.3 | 204.95 | 0.0516 |
630 | 732 | 61 | 3.91 | 35.19 | 2019.8 | 230.58 | 0.0458 |
710 | 825 | 61 | 4.15 | 37.35 | 2276.2 | 259.86 | 0.0407 |
800 | 930 | 61 | 4.40 | 39.6 | 2564.8 | 292.80 | 0.0361 |
900 | 1046 | 91 | 3.83 | 42.13 | 2888.3 | 329.40 | 0.0321 |
1000 | 1162 | 91 | 4.03 | 44.33 | 3209.3 | 366.00 | 0.0289 |
1120 | 1301 | 91 | 4.27 | 46.97 | 3594.4 | 409.92 | 0.0258 |

We always consider the needs of customers as our quest, and try our best to provide wholeheartedly high-quality Earth Grounding Cable 10mm and first-rate services to customers at home and abroad to create a brighter future. With the spirit of "integrity, service, quality and innovation" and the eternal goal of "pursuing outstanding performance" and "customer satisfaction", we sincerely hope to establish long-term relationships with our customers. We sincerely hope to establish a long-term, mutual trust, open and mutually beneficial strategic partnership with our customers. We implement fine management, pay attention to quality and detail.
Hot Tags: aaac conductor, China, suppliers, manufacturers, factory, wholesale, price, in stock, price list, made in China, 11kv 3 core xlpe cable, 2 Core PV Solar Cable, Transparent Speaker Cable, Spiral Cable For Truck, FTP Cat5e Cable, outdoor utp cable cat5e