Aaac Conductor

Aaac Conductor

1.AAAC conductor as our hot sales item,we can produce according to different standards such as GB, IEC, BS,ASTM, DIN and so on.
2.More than 15 years experience in power cable field,We have engineer team that can design suitable product for power project.
Send Inquiry
Description

AAAC Aaac Conductor -All Aluminum Alloy Conductor

1.Bare AAAC conductor is usually used for power transmission line project.

2.We are familiar with different international standards with IEC,BS,DIN, ASTM.We an supply very professional service for customer.

3.Packing: in drums in 2000m or 3000m according to customer’s requirement

4.Delivery: about 50km production per day


AAAC Conductor (JLHA1)

Standard: Chinese Standard GB/T 1179-2008

Nominal Aera

mm2

Code Number

Calculated Area

mm2


Number of Wires

Diameter

Rated Strength

KN

Max. D.C. Resistance at

20℃ ≤Ω/km

Wire

mm

OD

mm

20

16

18.6

7

1.84

5.52

6.04

1.7896

30

25

29.0

7

2.30

6.90

9.44

1.1453

45

40

46.5

7

2.91

8.72

15.10

0.7158

75

63

73.2

7

3.65

10.9

23.06

0.4545

120

100

116

19

2.79

14.0

37.76

0.2877

145

125

145

19

3.12

15.6

47.20

0.2302

185

160

186

19

3.53

17.6

58.56

0.1798

230

200

232

19

3.95

19.7

73.20

0.1439

300

250

290

19

4.41

22.1

91.50

0.1151

360

315

366

37

3.55

24.8

115.29

0.0916

465

400

465

37

4.00

28.0

146.40

0.0721

520

450

523

37

4.24

29.7

164.70

0.0641

580

500

581

37

4.47

31.3

183.00

0.0577

650

560

651

61

3.69

33.2

204.96

0.0516

720

630

732

61

3.91

35.2

230.58

0.0458

825

710

825

61

4.15

37.3

259.86

0.0407

930

800

930

61

4.40

39.6

292.80

0.0361

1050

900

1046

91

3.83

42.1

329.40

0.0321

1150

1000

1162

91

4.03

44.4

366.00

0.0289

1300

1120

1301

91

4.27

46.9

409.92

0.0258


AAAC  Conductor

Standard: ASTM B399

Code name

Area

No./wire diameter

Overall diameter

Weight

Nominal breaking load

Standard length

Nominal

Actual


MCM

mm2

mm

mm

Kg/km

KN

m±5%

Akron

30.58

15.48

7/1.68

5.04

42.7

4.92

3000

Alton

48.69

24.71

7/2.12

6.35

68.0

7.84

3000

Ames

77.47

39.22

7/2.67

8.02

108

12.45

2000

Azusa

123.3

62.38

7/3.37

10.11

172

18.97

2000

Anaheim

155.4

78.65

7/3.78

11.35

217

23.93

3000

Amherst

195.7

99.22

7/4.25

12.75

273

30.18

2500

Alliance

246.9

125.1

7/4.77

14.31

345

38.05

2000

Butte

312.8

158.6

19/3.26

16.30

437

48.76

3000

Canton

394.5

199.9

19/3.66

18.30

551

58.91

2500

Cairo

465.4

235.8

19/3.98

19.88

650

69.48

2000

Darien

559.5

283.5

19/4.36

21.79

781

83.52

2000

Elgin

652.4

330.6

19/4.71

23.54

911

97.42

1500

Flint

740.8

375.3

37/3.59

25.16

1035

108.21

3000

Greely

927.2

469.8

37/4.02

28.14

1295

135.47

2500


AAAC conductor

Standard: ASTM B399

Area

No./wire diameter

Overall diameter

Weight

Nominal breaking load

Max D.C. resistance at 20℃

Standard length

Nominal

Actual

AWG or MCM

mm2

mm

mm

Kg/km

KN

Ω/km

m±5%

6

13.30

7/1.554

4.67

37

4.22

2.5199

3500

4

21.15

7/1.961

5.89

58

6.71

1.5824

3000

2

33.63

7/2.474

7.42

93

10.68

0.9942

2500

1/0

53.48

7/3.119

9.36

148

16.97

0.6256

2000

2/0

67.42

7/3.503

10.51

186

20.52

0.4959

3500

3/0

85.03

7/3.932

11.80

234

25.86

0.3939

3000

4/0

107.23

7/4.417

13.26

296

32.63

0.3119

2000

250

126.66

19/2.913

14.57

349

38.93

0.2642

2000

300

152.10

19/3.193

15.97

419

46.77

0.2199

3000

350

177.35

19/3.447

17.24

489

52.25

0.1887

3000

400

202.71

19/3.686

18.43

559

59.74

0.1650

2500

450

228.00

19/3.909

19.66

629

67.19

0.1467

2000

500

253.35

19/4.120

20.60

698

74.64

0.1321

2000

550

278.60

37/3.096

21.67

768

83.80

0.1202

2000

600

303.80

37/3.233

22.63

838

91.38

0.1102

2000

650

329.25

37/3.366

23.56

908

97.94

0.1016

2000

700

354.55

37/3.493

24.45

978

102.20

0.0944

3500

750

380.20

37/3.617

25.32

1049

109.60

0.0880

3000

800

405.15

37/3.734

26.14

1117

116.80

0.0826

3000

900

456.16

37/3.962

27.73

1258

131.50

0.0733

3000

1000

506.71

37/4.176

29.23

1399

146.10

0.0660

2500


AAAC Conductor Cable

Standard: BS EN50183

Code name

Calculated area

No of wires

Diameter

Weight

Rated strength

Max D.C.

resistance at 20℃

Wire

Cond


mm2


mm

mm

Kg/km

KN

Ω/km

Box

18.8

7

1.85

5.55

51.4

5.55

1.7480

Acacia

23.8

7

2.08

6.24

64.9

7.02

1.3828

Almond

30.1

7

2.34

7.02

82.2

8.88

1.0926

Cedar

35.5

7

2.54

7.62

96.8

10.46

0.9273

Deodar

42.2

7

2.77

8.31

115.2

12.44

0.7797

Fir

47.8

7

2.95

8.85

130.6

14.11

0.6875

Hazel

59.9

7

3.30

9.90

163.4

17.66

0.5494

Pine

71.6

7

3.61

10.8

195.6

21.14

0.4591

Holly

84.1

7

3.91

11.7

229.5

24.79

0.3913

Willow

89.7

7

4.04

12.1

245.0

26.47

0.3665

Oak

118.9

7

4.65

14.0

324.5

65.07

0.2767

Mulberry

150.9

19

3.18

15.9

414.3

44.52

0.2192

Ash

180.7

19

3.48

17.4

496.1

53.31

0.1830

Elm

211.0

19

3.76

18.8

579.2

62.24

0.1568

Poplar

239.4

37

2.87

20.1

659.4

70.61

0.1387

Sycamore

303.2

37

3.23

22.6

835.2

89.40

0.1095

Upas

362.1

37

3.53

24.7

997.5

106.82

0.0917

Yew

479.0

37

4.06

28.4

1319.6

141.31

0.0693

Totara

498.1

37

4.14

29.0

1372.1

145.93

0.0666

Rubus

586.9

61

3.50

31.5

1622.0

173.13

0.0567

Sorbus

659.4

61

3.71

33.4

1822.5

194.53

0.0505

Araucaria

821.1

61

4.14

37.3

2269.4

242.24

0.0406

Redwood

996.2

61

4.56

41.0

2753.2

293.88

0.0334


AAAC

Standard: BS 3242

Code name

Nominal area

No of wires

Diameter

Weight

Rated strength

Max D.C.

resistance at 20℃

Wire

Cond


mm2


mm

mm

Kg/km

KN

Ω/km

Box

15

7

1.85

5.55

51

5.37

1.7495

Acacia

20

7

2.08

6.24

65

6.80

1.3840

Almond

25

7

2.34

7.02

82

8.61

1.0934

Cedar

30

7

2.54

7.62

97

10.14

0.9281

-

35

7

2.77

8.31

115

12.05

0.7804

Fir

40

7

2.95

8.85

131

13.67

0.6880

Hazel

50

7

3.30

9.90

164

17.11

0.5498

Pine

60

7

3.61

10.83

196

20.48

0.4594

-

70

7

3.91

11.73

230

24.02

0.3917

Willow

75

7

4.04

12.12

245

25.65

0.3669

-

80

7

4.19

12.57

264

27.58

0..3441

-

90

7

4.44

13.32

298

31.12

0.3023

Oak

100

7

4.65

13.95

325

33.98

0.2769

-

100

19

2.82

14.1

326

33.93

0.2787

Mulberry

125

19

3.18

15.9

415

43.12

0.2192

Ash

150

19

3.48

17.4

497

51.64

0.1831

Elm

175

19

3.76

18.8

580

60.30

0.1568

Poplar

200

37

2.87

20.09

659

88.41

0.1385

-

225

37

3.05

21.35

744

77.24

0.1227

Sycamore

250

37

3.22

22.54

835

86.64

0.1093

Upas

300

37

3.53

24.71

997

103.50

0.09156

Walnut

350

37

3.81

26.67

1162

120.53

0.07860

Yew

400

37

4.06

28.42

1319

136.85

0.06921

Totara

425

37

4.14

28.98

1372

142.33

0.06656

Rubus

500

61

3.50

31.5

1620

167.71

0.05662

Sorbus

659.4

61

3.71

33.4

1822.5

194.53

0.0505

Araucaria

700

61

4.14

37.26

2266

234.50

0.04047


AAAC

Standard: DIN 48201

Code number

Calculated area

No of wires

Diameter

Weight

Rated tensile strength

Max D.C.

resistance at 20℃

Wire

Cond

mm2

mm2


mm

mm

Kg/km

daN

Ω/km

16

15.89

7

1.70

5.1

43

444

2.0910

25

24.25

7

2.10

6.3

66

677

1.3703

35

34.36

7

2.50

7.5

94

960

0.9669

50

49.48

7

3.00

9.0

135

1382

0.6714

50

48.35

19

1.80

9.0

133

1350

0.6905

70

65.81

19

2.10

10.5

181

1838

0.5073

95

93.27

19

2.50

12.5

256

2605

0.3579

120

116.99

19

2.80

14.0

322

3268

0.2854

150

147.11

37

2.25

15.8

406

4109

0.2274

185

181.62

37

2.50

17.5

500

5073

0.1842

240

242.54

61

2.25

20.3

670

6774

0.1383

300

299.43

61

2.50

22.5

827

8363

0.1120

400

400.14

61

2.89

26.0

1104

11176

0.0838

500

499.63

61

3.23

29.1

1379

13960

0.06709

625

626.20

91

2.96

32.6

1732

17490

0.0540

800

802.09

91

3.35

36.9

2218

22402

0.0418

1000

999.71

91

3.74

41.1

2767

27922

0.0335


AAAC(Characteristics of A2 Conductors)

Standard: IEC 61089

Code Number


Calculated

Area


Number of Wires

Diameter of Wire

Diameter of Cond.

Linear Mass

Rated

Strength

Max.D.C.

Resistance

At 20℃

mm2

mm2


mm

mm

kg/km

kN

Ω/km

16

18.4

7

1.83

5.49

50.4

5.43

1.7896

25

28.8

7

2.29

6.87

78.7

8.49

1.1453

40

46.0

7

2.89

8.67

125.9

13.58

0.7158

63

72.5

7

3.63

10.8

198.3

21.39

0.4545

100

115

19

2.78

13.9

316.3

33.95

0.2877

125

144

19

3.10

15.5

395.4

42.44

0.2302

160

184

19

3.51

17.55

506.1

54.32

0.1798

200

230

19

3.93

19.65

632.7

67.91

0.1439

250

288

19

4.39

21.95

790.8

84.68

0.1151

315

363

37

3.53

24.71

998.9

106.95

0.0916

400

460

37

3.98

27.86

1268.4

135.81

0.0721

450

518

37

4.22

29.54

1426.9

152.79

0.0641

500

575

37

4.45

31.15

1585.5

169.76

0.0577

560

645

61

3.67

33.03

1778.4

190.14

0.0516

630

725

61

3.89

35.01

2000.7

213.90

0.0458

710

817

61

4.13

37.17

2254.8

241.07

0.0407

800

921

61

4.38

39.42

2540.6

271.62

0.0361

900

1036

91

3.81

41.91

2861.1

305.58

0.0632

1000

1151

91

4.01

44.11

3179.0

339.53

0.0289

1120

1289

91

4.25

46.75

3560.5

380.27

0.0258

1252

1439

91

4.49

49.39

3973.7

424.41

0.0231


AAAC(Characteristics of A3 Conductors)

Standard : IEC 61089

Code Number


Calculated

Area


Number of Wires

Diameter of Wire

Diameter of Cond.

Linear Mass

Rated

Strength

Max.D.C.

Resistance

At 20℃

mm2

mm2


mm

mm

kg/km

kN

Ω/km

16

18.6

7

1.84

5.52

50.8

6.04

1.7896

25

29.0

7

2.30

6.90

79.5

9.44

1.1453

40

46.5

7

2.91

8.73

127.1

15.10

0.7158

63

73.2

7

3.65

10.95

200.2

23.06

0.4545

100

116

19

2.79

13.95

319.3

37.76

0.2877

125

145

19

3.12

15.6

399.2

47.20

0.2302

160

186

19

3.53

17.65

511.0

58.56

0.1798

200

232

19

3.95

19.75

638.7

73.20

0.1439

250

290

19

4.41

22.05

798.4

91.50

0.1151

315

366

37

3.55

24.85

1008.4

115.29

0.0916

400

465

37

4.00

28.0

1280.5

146.40

0.0721

450

523

37

4.24

29.68

1440.5

164.70

0.0641

500

581

37

4.47

31.29

1600.6

183.00

0.0577

560

651

61

3.69

33.21

1795.3

204.95

0.0516

630

732

61

3.91

35.19

2019.8

230.58

0.0458

710

825

61

4.15

37.35

2276.2

259.86

0.0407

800

930

61

4.40

39.6

2564.8

292.80

0.0361

900

1046

91

3.83

42.13

2888.3

329.40

0.0321

1000

1162

91

4.03

44.33

3209.3

366.00

0.0289

1120

1301

91

4.27

46.97

3594.4

409.92

0.0258


Aaac Conductor suppliers

Aaac Conductor manufacturers

Hot Tags: aaac conductor, China, suppliers, manufacturers, factory, wholesale, price, in stock, price list, made in China, Aac Conductor, Earth Ground Cable, ACSR Bare Conductor, High Voltage Cable, Bare Copper Earth Cable, Aaac Conductor

Send Inquiry

(0/10)

clearall