The quality of product packaging is becoming more and more important, directly affecting 2 Core PV Solar Cable, White Spiral Cable, 110KV XLPE Cable quality and sales and the honor and benefits of the manufacturing enterprise, and is increasingly valued by consumers and enterprises. A number of technical products developed by the company have been provided to customers at home and abroad for trial, and have been well received in terms of performance and quality. Innovation, the pursuit of excellence, teamwork is our company requires employees to have the style of work.
AAAC Aaac Conductor -All Aluminum Alloy Conductor
1.Bare AAAC conductor is usually used for power transmission line project.
2.We are familiar with different international standards with IEC,BS,DIN, ASTM.We an supply very professional service for customer.
3.Packing: in drums in 2000m or 3000m according to customer’s requirement
4.Delivery: about 50km production per day
AAAC Conductor (JLHA1)
Standard: Chinese Standard GB/T 1179-2008
Nominal Aera mm2 | Code Number | Calculated Area mm2 | Number of Wires | Diameter | Rated Strength KN | Max. D.C. Resistance at 20℃ ≤Ω/km | |
Wire mm | OD mm | ||||||
20 | 16 | 18.6 | 7 | 1.84 | 5.52 | 6.04 | 1.7896 |
30 | 25 | 29.0 | 7 | 2.30 | 6.90 | 9.44 | 1.1453 |
45 | 40 | 46.5 | 7 | 2.91 | 8.72 | 15.10 | 0.7158 |
75 | 63 | 73.2 | 7 | 3.65 | 10.9 | 23.06 | 0.4545 |
120 | 100 | 116 | 19 | 2.79 | 14.0 | 37.76 | 0.2877 |
145 | 125 | 145 | 19 | 3.12 | 15.6 | 47.20 | 0.2302 |
185 | 160 | 186 | 19 | 3.53 | 17.6 | 58.56 | 0.1798 |
230 | 200 | 232 | 19 | 3.95 | 19.7 | 73.20 | 0.1439 |
300 | 250 | 290 | 19 | 4.41 | 22.1 | 91.50 | 0.1151 |
360 | 315 | 366 | 37 | 3.55 | 24.8 | 115.29 | 0.0916 |
465 | 400 | 465 | 37 | 4.00 | 28.0 | 146.40 | 0.0721 |
520 | 450 | 523 | 37 | 4.24 | 29.7 | 164.70 | 0.0641 |
580 | 500 | 581 | 37 | 4.47 | 31.3 | 183.00 | 0.0577 |
650 | 560 | 651 | 61 | 3.69 | 33.2 | 204.96 | 0.0516 |
720 | 630 | 732 | 61 | 3.91 | 35.2 | 230.58 | 0.0458 |
825 | 710 | 825 | 61 | 4.15 | 37.3 | 259.86 | 0.0407 |
930 | 800 | 930 | 61 | 4.40 | 39.6 | 292.80 | 0.0361 |
1050 | 900 | 1046 | 91 | 3.83 | 42.1 | 329.40 | 0.0321 |
1150 | 1000 | 1162 | 91 | 4.03 | 44.4 | 366.00 | 0.0289 |
1300 | 1120 | 1301 | 91 | 4.27 | 46.9 | 409.92 | 0.0258 |
AAAC Conductor
Standard: ASTM B399
Code name | Area | No./wire diameter | Overall diameter | Weight | Nominal breaking load | Standard length | |
Nominal | Actual | ||||||
MCM | mm2 | mm | mm | Kg/km | KN | m±5% | |
Akron | 30.58 | 15.48 | 7/1.68 | 5.04 | 42.7 | 4.92 | 3000 |
Alton | 48.69 | 24.71 | 7/2.12 | 6.35 | 68.0 | 7.84 | 3000 |
Ames | 77.47 | 39.22 | 7/2.67 | 8.02 | 108 | 12.45 | 2000 |
Azusa | 123.3 | 62.38 | 7/3.37 | 10.11 | 172 | 18.97 | 2000 |
Anaheim | 155.4 | 78.65 | 7/3.78 | 11.35 | 217 | 23.93 | 3000 |
Amherst | 195.7 | 99.22 | 7/4.25 | 12.75 | 273 | 30.18 | 2500 |
Alliance | 246.9 | 125.1 | 7/4.77 | 14.31 | 345 | 38.05 | 2000 |
Butte | 312.8 | 158.6 | 19/3.26 | 16.30 | 437 | 48.76 | 3000 |
Canton | 394.5 | 199.9 | 19/3.66 | 18.30 | 551 | 58.91 | 2500 |
Cairo | 465.4 | 235.8 | 19/3.98 | 19.88 | 650 | 69.48 | 2000 |
Darien | 559.5 | 283.5 | 19/4.36 | 21.79 | 781 | 83.52 | 2000 |
Elgin | 652.4 | 330.6 | 19/4.71 | 23.54 | 911 | 97.42 | 1500 |
Flint | 740.8 | 375.3 | 37/3.59 | 25.16 | 1035 | 108.21 | 3000 |
Greely | 927.2 | 469.8 | 37/4.02 | 28.14 | 1295 | 135.47 | 2500 |
AAAC conductor
Standard: ASTM B399
Area | No./wire diameter | Overall diameter | Weight | Nominal breaking load | Max D.C. resistance at 20℃ | Standard length | |
Nominal | Actual | ||||||
AWG or MCM | mm2 | mm | mm | Kg/km | KN | Ω/km | m±5% |
6 | 13.30 | 7/1.554 | 4.67 | 37 | 4.22 | 2.5199 | 3500 |
4 | 21.15 | 7/1.961 | 5.89 | 58 | 6.71 | 1.5824 | 3000 |
2 | 33.63 | 7/2.474 | 7.42 | 93 | 10.68 | 0.9942 | 2500 |
1/0 | 53.48 | 7/3.119 | 9.36 | 148 | 16.97 | 0.6256 | 2000 |
2/0 | 67.42 | 7/3.503 | 10.51 | 186 | 20.52 | 0.4959 | 3500 |
3/0 | 85.03 | 7/3.932 | 11.80 | 234 | 25.86 | 0.3939 | 3000 |
4/0 | 107.23 | 7/4.417 | 13.26 | 296 | 32.63 | 0.3119 | 2000 |
250 | 126.66 | 19/2.913 | 14.57 | 349 | 38.93 | 0.2642 | 2000 |
300 | 152.10 | 19/3.193 | 15.97 | 419 | 46.77 | 0.2199 | 3000 |
350 | 177.35 | 19/3.447 | 17.24 | 489 | 52.25 | 0.1887 | 3000 |
400 | 202.71 | 19/3.686 | 18.43 | 559 | 59.74 | 0.1650 | 2500 |
450 | 228.00 | 19/3.909 | 19.66 | 629 | 67.19 | 0.1467 | 2000 |
500 | 253.35 | 19/4.120 | 20.60 | 698 | 74.64 | 0.1321 | 2000 |
550 | 278.60 | 37/3.096 | 21.67 | 768 | 83.80 | 0.1202 | 2000 |
600 | 303.80 | 37/3.233 | 22.63 | 838 | 91.38 | 0.1102 | 2000 |
650 | 329.25 | 37/3.366 | 23.56 | 908 | 97.94 | 0.1016 | 2000 |
700 | 354.55 | 37/3.493 | 24.45 | 978 | 102.20 | 0.0944 | 3500 |
750 | 380.20 | 37/3.617 | 25.32 | 1049 | 109.60 | 0.0880 | 3000 |
800 | 405.15 | 37/3.734 | 26.14 | 1117 | 116.80 | 0.0826 | 3000 |
900 | 456.16 | 37/3.962 | 27.73 | 1258 | 131.50 | 0.0733 | 3000 |
1000 | 506.71 | 37/4.176 | 29.23 | 1399 | 146.10 | 0.0660 | 2500 |
AAAC Conductor Cable
Standard: BS EN50183
Code name | Calculated area | No of wires | Diameter | Weight | Rated strength | Max D.C. resistance at 20℃ | |
Wire | Cond | ||||||
mm2 | mm | mm | Kg/km | KN | Ω/km | ||
Box | 18.8 | 7 | 1.85 | 5.55 | 51.4 | 5.55 | 1.7480 |
Acacia | 23.8 | 7 | 2.08 | 6.24 | 64.9 | 7.02 | 1.3828 |
Almond | 30.1 | 7 | 2.34 | 7.02 | 82.2 | 8.88 | 1.0926 |
Cedar | 35.5 | 7 | 2.54 | 7.62 | 96.8 | 10.46 | 0.9273 |
Deodar | 42.2 | 7 | 2.77 | 8.31 | 115.2 | 12.44 | 0.7797 |
Fir | 47.8 | 7 | 2.95 | 8.85 | 130.6 | 14.11 | 0.6875 |
Hazel | 59.9 | 7 | 3.30 | 9.90 | 163.4 | 17.66 | 0.5494 |
Pine | 71.6 | 7 | 3.61 | 10.8 | 195.6 | 21.14 | 0.4591 |
Holly | 84.1 | 7 | 3.91 | 11.7 | 229.5 | 24.79 | 0.3913 |
Willow | 89.7 | 7 | 4.04 | 12.1 | 245.0 | 26.47 | 0.3665 |
Oak | 118.9 | 7 | 4.65 | 14.0 | 324.5 | 65.07 | 0.2767 |
Mulberry | 150.9 | 19 | 3.18 | 15.9 | 414.3 | 44.52 | 0.2192 |
Ash | 180.7 | 19 | 3.48 | 17.4 | 496.1 | 53.31 | 0.1830 |
Elm | 211.0 | 19 | 3.76 | 18.8 | 579.2 | 62.24 | 0.1568 |
Poplar | 239.4 | 37 | 2.87 | 20.1 | 659.4 | 70.61 | 0.1387 |
Sycamore | 303.2 | 37 | 3.23 | 22.6 | 835.2 | 89.40 | 0.1095 |
Upas | 362.1 | 37 | 3.53 | 24.7 | 997.5 | 106.82 | 0.0917 |
Yew | 479.0 | 37 | 4.06 | 28.4 | 1319.6 | 141.31 | 0.0693 |
Totara | 498.1 | 37 | 4.14 | 29.0 | 1372.1 | 145.93 | 0.0666 |
Rubus | 586.9 | 61 | 3.50 | 31.5 | 1622.0 | 173.13 | 0.0567 |
Sorbus | 659.4 | 61 | 3.71 | 33.4 | 1822.5 | 194.53 | 0.0505 |
Araucaria | 821.1 | 61 | 4.14 | 37.3 | 2269.4 | 242.24 | 0.0406 |
Redwood | 996.2 | 61 | 4.56 | 41.0 | 2753.2 | 293.88 | 0.0334 |
AAAC
Standard: BS 3242
Code name | Nominal area | No of wires | Diameter | Weight | Rated strength | Max D.C. resistance at 20℃ | |
Wire | Cond | ||||||
mm2 | mm | mm | Kg/km | KN | Ω/km | ||
Box | 15 | 7 | 1.85 | 5.55 | 51 | 5.37 | 1.7495 |
Acacia | 20 | 7 | 2.08 | 6.24 | 65 | 6.80 | 1.3840 |
Almond | 25 | 7 | 2.34 | 7.02 | 82 | 8.61 | 1.0934 |
Cedar | 30 | 7 | 2.54 | 7.62 | 97 | 10.14 | 0.9281 |
- | 35 | 7 | 2.77 | 8.31 | 115 | 12.05 | 0.7804 |
Fir | 40 | 7 | 2.95 | 8.85 | 131 | 13.67 | 0.6880 |
Hazel | 50 | 7 | 3.30 | 9.90 | 164 | 17.11 | 0.5498 |
Pine | 60 | 7 | 3.61 | 10.83 | 196 | 20.48 | 0.4594 |
- | 70 | 7 | 3.91 | 11.73 | 230 | 24.02 | 0.3917 |
Willow | 75 | 7 | 4.04 | 12.12 | 245 | 25.65 | 0.3669 |
- | 80 | 7 | 4.19 | 12.57 | 264 | 27.58 | 0..3441 |
- | 90 | 7 | 4.44 | 13.32 | 298 | 31.12 | 0.3023 |
Oak | 100 | 7 | 4.65 | 13.95 | 325 | 33.98 | 0.2769 |
- | 100 | 19 | 2.82 | 14.1 | 326 | 33.93 | 0.2787 |
Mulberry | 125 | 19 | 3.18 | 15.9 | 415 | 43.12 | 0.2192 |
Ash | 150 | 19 | 3.48 | 17.4 | 497 | 51.64 | 0.1831 |
Elm | 175 | 19 | 3.76 | 18.8 | 580 | 60.30 | 0.1568 |
Poplar | 200 | 37 | 2.87 | 20.09 | 659 | 88.41 | 0.1385 |
- | 225 | 37 | 3.05 | 21.35 | 744 | 77.24 | 0.1227 |
Sycamore | 250 | 37 | 3.22 | 22.54 | 835 | 86.64 | 0.1093 |
Upas | 300 | 37 | 3.53 | 24.71 | 997 | 103.50 | 0.09156 |
Walnut | 350 | 37 | 3.81 | 26.67 | 1162 | 120.53 | 0.07860 |
Yew | 400 | 37 | 4.06 | 28.42 | 1319 | 136.85 | 0.06921 |
Totara | 425 | 37 | 4.14 | 28.98 | 1372 | 142.33 | 0.06656 |
Rubus | 500 | 61 | 3.50 | 31.5 | 1620 | 167.71 | 0.05662 |
Sorbus | 659.4 | 61 | 3.71 | 33.4 | 1822.5 | 194.53 | 0.0505 |
Araucaria | 700 | 61 | 4.14 | 37.26 | 2266 | 234.50 | 0.04047 |
AAAC
Standard: DIN 48201
Code number | Calculated area | No of wires | Diameter | Weight | Rated tensile strength | Max D.C. resistance at 20℃ | |
Wire | Cond | ||||||
mm2 | mm2 | mm | mm | Kg/km | daN | Ω/km | |
16 | 15.89 | 7 | 1.70 | 5.1 | 43 | 444 | 2.0910 |
25 | 24.25 | 7 | 2.10 | 6.3 | 66 | 677 | 1.3703 |
35 | 34.36 | 7 | 2.50 | 7.5 | 94 | 960 | 0.9669 |
50 | 49.48 | 7 | 3.00 | 9.0 | 135 | 1382 | 0.6714 |
50 | 48.35 | 19 | 1.80 | 9.0 | 133 | 1350 | 0.6905 |
70 | 65.81 | 19 | 2.10 | 10.5 | 181 | 1838 | 0.5073 |
95 | 93.27 | 19 | 2.50 | 12.5 | 256 | 2605 | 0.3579 |
120 | 116.99 | 19 | 2.80 | 14.0 | 322 | 3268 | 0.2854 |
150 | 147.11 | 37 | 2.25 | 15.8 | 406 | 4109 | 0.2274 |
185 | 181.62 | 37 | 2.50 | 17.5 | 500 | 5073 | 0.1842 |
240 | 242.54 | 61 | 2.25 | 20.3 | 670 | 6774 | 0.1383 |
300 | 299.43 | 61 | 2.50 | 22.5 | 827 | 8363 | 0.1120 |
400 | 400.14 | 61 | 2.89 | 26.0 | 1104 | 11176 | 0.0838 |
500 | 499.63 | 61 | 3.23 | 29.1 | 1379 | 13960 | 0.06709 |
625 | 626.20 | 91 | 2.96 | 32.6 | 1732 | 17490 | 0.0540 |
800 | 802.09 | 91 | 3.35 | 36.9 | 2218 | 22402 | 0.0418 |
1000 | 999.71 | 91 | 3.74 | 41.1 | 2767 | 27922 | 0.0335 |
AAAC(Characteristics of A2 Conductors)
Standard: IEC 61089
Code Number | Calculated Area | Number of Wires | Diameter of Wire | Diameter of Cond. | Linear Mass | Rated Strength | Max.D.C. Resistance At 20℃ |
mm2 | mm2 | mm | mm | kg/km | kN | Ω/km | |
16 | 18.4 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 1.7896 |
25 | 28.8 | 7 | 2.29 | 6.87 | 78.7 | 8.49 | 1.1453 |
40 | 46.0 | 7 | 2.89 | 8.67 | 125.9 | 13.58 | 0.7158 |
63 | 72.5 | 7 | 3.63 | 10.8 | 198.3 | 21.39 | 0.4545 |
100 | 115 | 19 | 2.78 | 13.9 | 316.3 | 33.95 | 0.2877 |
125 | 144 | 19 | 3.10 | 15.5 | 395.4 | 42.44 | 0.2302 |
160 | 184 | 19 | 3.51 | 17.55 | 506.1 | 54.32 | 0.1798 |
200 | 230 | 19 | 3.93 | 19.65 | 632.7 | 67.91 | 0.1439 |
250 | 288 | 19 | 4.39 | 21.95 | 790.8 | 84.68 | 0.1151 |
315 | 363 | 37 | 3.53 | 24.71 | 998.9 | 106.95 | 0.0916 |
400 | 460 | 37 | 3.98 | 27.86 | 1268.4 | 135.81 | 0.0721 |
450 | 518 | 37 | 4.22 | 29.54 | 1426.9 | 152.79 | 0.0641 |
500 | 575 | 37 | 4.45 | 31.15 | 1585.5 | 169.76 | 0.0577 |
560 | 645 | 61 | 3.67 | 33.03 | 1778.4 | 190.14 | 0.0516 |
630 | 725 | 61 | 3.89 | 35.01 | 2000.7 | 213.90 | 0.0458 |
710 | 817 | 61 | 4.13 | 37.17 | 2254.8 | 241.07 | 0.0407 |
800 | 921 | 61 | 4.38 | 39.42 | 2540.6 | 271.62 | 0.0361 |
900 | 1036 | 91 | 3.81 | 41.91 | 2861.1 | 305.58 | 0.0632 |
1000 | 1151 | 91 | 4.01 | 44.11 | 3179.0 | 339.53 | 0.0289 |
1120 | 1289 | 91 | 4.25 | 46.75 | 3560.5 | 380.27 | 0.0258 |
1252 | 1439 | 91 | 4.49 | 49.39 | 3973.7 | 424.41 | 0.0231 |
AAAC(Characteristics of A3 Conductors)
Standard : IEC 61089
Code Number | Calculated Area | Number of Wires | Diameter of Wire | Diameter of Cond. | Linear Mass | Rated Strength | Max.D.C. Resistance At 20℃ |
mm2 | mm2 | mm | mm | kg/km | kN | Ω/km | |
16 | 18.6 | 7 | 1.84 | 5.52 | 50.8 | 6.04 | 1.7896 |
25 | 29.0 | 7 | 2.30 | 6.90 | 79.5 | 9.44 | 1.1453 |
40 | 46.5 | 7 | 2.91 | 8.73 | 127.1 | 15.10 | 0.7158 |
63 | 73.2 | 7 | 3.65 | 10.95 | 200.2 | 23.06 | 0.4545 |
100 | 116 | 19 | 2.79 | 13.95 | 319.3 | 37.76 | 0.2877 |
125 | 145 | 19 | 3.12 | 15.6 | 399.2 | 47.20 | 0.2302 |
160 | 186 | 19 | 3.53 | 17.65 | 511.0 | 58.56 | 0.1798 |
200 | 232 | 19 | 3.95 | 19.75 | 638.7 | 73.20 | 0.1439 |
250 | 290 | 19 | 4.41 | 22.05 | 798.4 | 91.50 | 0.1151 |
315 | 366 | 37 | 3.55 | 24.85 | 1008.4 | 115.29 | 0.0916 |
400 | 465 | 37 | 4.00 | 28.0 | 1280.5 | 146.40 | 0.0721 |
450 | 523 | 37 | 4.24 | 29.68 | 1440.5 | 164.70 | 0.0641 |
500 | 581 | 37 | 4.47 | 31.29 | 1600.6 | 183.00 | 0.0577 |
560 | 651 | 61 | 3.69 | 33.21 | 1795.3 | 204.95 | 0.0516 |
630 | 732 | 61 | 3.91 | 35.19 | 2019.8 | 230.58 | 0.0458 |
710 | 825 | 61 | 4.15 | 37.35 | 2276.2 | 259.86 | 0.0407 |
800 | 930 | 61 | 4.40 | 39.6 | 2564.8 | 292.80 | 0.0361 |
900 | 1046 | 91 | 3.83 | 42.13 | 2888.3 | 329.40 | 0.0321 |
1000 | 1162 | 91 | 4.03 | 44.33 | 3209.3 | 366.00 | 0.0289 |
1120 | 1301 | 91 | 4.27 | 46.97 | 3594.4 | 409.92 | 0.0258 |

We take 'strengthening management, optimizing service, quality first, reputation first' as our tenet, and provide you with excellent Power Transmission Line Overhead Bare Aluminum Conductors ACSR AAC AAAC Acss Acar Conductor at a price-performance ratio. At present, we have established good strategic partnership with many enterprises, and have independent R&D team. With advanced production equipment, strong technical force, rich experience and reasonable price, we provide customers with quality service and create a more brilliant future for the company.