Honest and trustworthy, rigorous and down-to-earth is our company's consistent work style. Over the past few years, we have made unremitting efforts and made pioneering efforts to occupy a place in the FEP Wire, cable tsj 3x12, 110KV XLPE Cable industry. We adhere to the coexistence of brand and quality, talent and career. The company adheres to the tenet of "survive by quality and development by service" and the concept of "integrity, pragmatism, innovation, and progress". We welcome new and old customers to come to technical exchanges and cooperation. We insist on original design, aiming to provide users with all-round choices, and also enrich product resources for cooperative customers. Our company always provides good quality and reasonable price for our customers.
Description: High Voltage XLPE Cable XLPE insulated Electric Power Cable
Hot export specification: 240mm, 300mm2, 400mm2, 630mm2
Application of High Voltage XLPE Cable
HV power cable can be used for power plant and substation.It is suitable for use in power transmission and distribution lines with rated power frequency voltage 48/66kV,64/110kV, 76/132kV
Type name of High Voltage XLPE Cable
YJLW02: corrugated aluminum inner sheath, PVC Jacket
YJLW03: corrugated aluminum inner sheath, PE Jacket
YJQ02: Lead inner sheath,PVC Jacket
YJQ03: Lead inner sheath,PE Jacket
Standard: GB/T 11017,IEC 60840
This product by GB11017 "rated voltage of 110 kV copper, Aluminum core XLPE power cable" and IEC60840 "rated voltage 30 kV to 150kV power
cable insulation crowded pack test" standard.
Using characteristics
Rated power-frequency voltage U0/U: 48/66kV,64/110kV,76/132kV.
Max. permissible continuous operating temperature of conductor: 90ºC.
Max. short-circuit temperature
of conductor shall not exceed 250ºC(5s maximum duration).
The ambient temperature under installation should not below 0ºC.
The bending radius should not less than 25 times of the cable diameter.
Application & Laying place
For laying indoors, underground laying directly buried,in tunnel, conduit, able to bear external mechanical forces and certain pulling force.
Technical Parameters:
Section area | Insulation Thickness | Metallic Sheath Thickness | Sheath Thickness | Overall Diameter | Calculated Cable Weight | Max. D.C. Conductor Resistance at 20°C |
No.x mm2 | mm | mm | mm | mm | kg/km | Ω/km |
48/66 kV | ||||||
1x185 | 14.5 | 2 | 4 | 68.3 | 5250 | 0.0991 |
1x240 | 14.5 | 2 | 4 | 76.7 | 5740 | 0.0754 |
1x300 | 14.5 | 2 | 4 | 79.1 | 6440 | 0.0601 |
1x400 | 14.5 | 2 | 4 | 82.3 | 7480 | 0.047 |
1x500 | 14.5 | 2 | 4 | 85.9 | 8750 | 0.0366 |
1x630 | 14.5 | 2 | 4 | 85.9 | 10360 | 0.0283 |
1x800 | 14.5 | 2 | 4 | 94.3 | 12260 | 0.0221 |
1x800 | 14.5 | 2 | 4 | 96.4 | 13790 | 0.0221 |
1x1000 | 14.5 | 2 | 4.5 | 102.8 | 15470 | 0.0176 |
1x1200 | 14.5 | 2 | 4.5 | 106.2 | 17580 | 0.0151 |
1x1400 | 14.5 | 2 | 5 | 110.4 | 20110 | 0.0129 |
1x1600 | 14.5 | 2 | 5 | 114.8 | 22510 | 0.0113 |
1x2000 | 14.5 | 2 | 5 | 121.8 | 27050 | 0.0009 |
64/110 kV | ||||||
1x240 | 19 | 2 | 4 | 85 | 7750 | 0.0754 |
1x300 | 18.5 | 2 | 4 | 86.1 | 8360 | 0.0601 |
1x400 | 17.5 | 2 | 4 | 86.9 | 9120 | 0.047 |
1x500 | 17 | 2 | 4 | 89.1 | 10260 | 0.0366 |
1x630 | 16.5 | 2 | 4.5 | 92.1 | 11750 | 0.0283 |
1x800 | 16 | 2 | 4.5 | 95 | 13520 | 0.0221 |
1x800 | 16 | 2 | 4.5 | 100 | 14320 | 0.0221 |
1x1000 | 16 | 2.3 | 4.5 | 105.4 | 16760 | 0.0176 |
1x1200 | 16 | 2.3 | 5 | 109.8 | 18900 | 0.0151 |
1x1400 | 16 | 2.3 | 5 | 114 | 21530 | 0.0129 |
1x1600 | 16 | 2.3 | 5 | 117.4 | 23930 | 0.0113 |
1x2000 | 16 | 2.3 | 5 | 124.4 | 27750 | 0.0009 |
127/220 kV | ||||||
1x300 | 27 | 2.4 | 5 | 112.5 | 10930 | 0.0601 |
1x400 | 27 | 2.4 | 5 | 118 | 11750 | 0.047 |
1x500 | 27 | 2.4 | 5 | 121.2 | 12880 | 0.0366 |
1x630 | 26 | 2.4 | 5 | 123 | 14320 | 0.0283 |
1x800 | 25 | 2.4 | 5 | 124.9 | 15720 | 0.0221 |
1x800 | 16 | 2 | 4.5 | 100 | 14320 | 0.0221 |
1x1000 | 24 | 2.6 | 5 | 129.4 | 20500 | 0.0176 |
1x1200 | 24 | 2.6 | 5 | 132.6 | 22810 | 0.0151 |
1x1400 | 24 | 2.6 | 5 | 136.8 | 25450 | 0.0129 |
1x1600 | 24 | 2.6 | 5 | 140.6 | 28050 | 0.0113 |
1x2000 | 24 | 2.8 | 5 | 147.5 | 32210 | 0.0009 |
Packing of High Voltage XLPE Cable:
Heat treated wooden drum, Steel Wooden drum, or Steel drum

Drawing for 110kv copper conductor xlpe insulated HV Power cable
Specifications:
1) 66KV -220kV XLPE insulated/copper or aluminum/corrugated aluminum sheathed/PVC
High Quality 66-220kV XLPE Insulated Power Cable-
66KV-220kV XLPE insulated power cable;
Construction:
Conductor : copper conductor, Or aluminum conductor
XLPE insulation, corrugated aluminum sheath, PVC / PE outer sheath,
longitudinal water-proof power cable
2) XLPE insulation, corrugated aluminum sheath, PVC / PE outer sheath,
longitudinal water-proof frame -resistant power cable
3) XLPE insulation, corrugated aluminum sheath,
PVC / PE outer sheath,
power cable
4) XLPE insulation, corrugated aluminum sheath, PVC / PE outer sheath,
fire-resistant power cable
Welcome to Visit Our Factory
Some Popular Products:
We are committed to become the world's large-scale, full range, precision manufacturing company of the High/Medium Voltage Cable Single Core 3 Core XLPE Insulation Armoured Power Supply Power Cable. Thanks to excellent performance and good sales service, our goods has be sold to man countries and regions, they are be well-accepted by local market. We will continue to strive for technology, work hard to improve the quality and services. We always adhere to the difference strategy to serve the global market with the best quality products.
Hot Tags: high voltage XLPE cable, China, suppliers, manufacturers, factory, wholesale, price, in stock, price list, made in China, shielded sensor cable, 4 core rubber flexible cable, rubber insulated welding cable, Spiral Coil Cable, Single Core PVC Insulated Cable, FTP Cat6 Cable