We've one of the most advanced generation tools, experienced and qualified engineers and workers, recognized good quality manage systems and a friendly skilled product sales workforce pre/after-sales support for Electric Cable, General Rubber Sheathed Flexible Cable, PVC Cable. At the beginning of its establishment, our company established the firm slogan of 'creating brand, we have been working hard'. With the joint efforts of all colleagues and the support of customers, our company has achieved good results. We always take the interests and needs of our customers as the foundation, and provide our users with cost-effective products meticulously, carefully and attentively. We help our customers achieve greater success with high quality technology, services and solutions.
AAC Conductor with full name : ALL ALUMINIUM STRANDED CONDUCTOR,
Type name as per Chinese standard: JL
Hot export to: Philippines, Indonesia, UAE, Saudi Arabia, South Africa, Nigeria, Kenya,many countries of Africa
Packing way: wooden drum or wooden steel drum
Aac Conductor Delivery: 50km production per day at least
Aac Conductor AAC Standard GB /T 1179-2008
Area | Pieces/Diameter | Diameter | Max. resistance At 20℃ | Calculation Force | Weight |
mm2 | mm | mm | Ω/km | KN | kg/km |
10 | 7/1.35 | 4.05 | 2.8633 | 1.95 | 27.4 |
16 | 7/1.71 | 5.12 | 1.7896 | 3.04 | 43.8 |
25 | 7/2.13 | 6.40 | 1.1453 | 4.50 | 68.4 |
40 | 7/2.70 | 8.09 | 0.7158 | 6.80 | 109.4 |
63 | 7/3.39 | 10.2 | 0.4545 | 10.39 | 172.3 |
100 | 19/2.59 | 12.9 | 0.2877 | 17.00 | 274.8 |
125 | 19/2.89 | 14.5 | 0.2302 | 21.25 | 343.6 |
160 | 19/3.27 | 16.4 | 0.1798 | 26.40 | 439.8 |
200 | 19/3.66 | 18.3 | 0.1439 | 32.00 | 549.7 |
250 | 19/4.09 | 20.5 | 0.1151 | 40.00 | 687.1 |
315 | 37/3.29 | 23.0 | 0.0916 | 51.97 | 867.9 |
400 | 37/3.71 | 26.0 | 0.0721 | 64.00 | 1102.0 |
450 | 37/3.94 | 27.5 | 0.0641 | 72.00 | 1239.8 |
500 | 37/4.15 | 29.0 | 0.0577 | 80.00 | 1377.6 |
560 | 37/4.39 | 30.7 | 0.0515 | 89.60 | 1542.9 |
630 | 61/3.63 | 32.6 | 0.0458 | 100.80 | 1738.3 |
710 | 61/3.85 | 34.6 | 0.0407 | 113.60 | 1959.1 |
800 | 61/4.09 | 36.8 | 0.0361 | 128.00 | 2207.4 |
900 | 61/4.33 | 39.0 | 0.0321 | 144.00 | 2483.3 |
1000 | 61/4.57 | 41.1 | 0.0289 | 160.00 | 2759.2 |
1120 | 91/3.96 | 43.5 | 0.0258 | 179.20 | 3093.5 |
1250 | 91/4.18 | 46.0 | 0.0231 | 200.00 | 3452.6 |
1400 | 91/4.43 | 48.7 | 0.0207 | 224.00 | 3866.9 |
1500 | 91/4.58 | 50.4 | 0.0193 | 240.00 | 4143.1 |
AAC
Standard: ASTM B231
Code Name | Total Area | Stranding and wire diameter mm | Linear Mass kg/km | Overall Diameter mm | Nominal Breaking Load daN | Max. D.C. Resistance at 20℃ ≤Ω/k | |
AWG or MCM | mm2 | ||||||
Peachbell | 6 | 13.29 | 7/1.554 | 37 | 4.67 | 249 | 2.1692 |
Rose | 4 | 21.16 | 7/1.961 | 58 | 5.89 | 396 | 1.3624 |
Iris | 2 | 33.61 | 7/2.474 | 93 | 7.42 | 597 | 0.8577 |
Pansy | 1 | 42.39 | 7/2.776 | 117 | 8.33 | 732 | 0.6801 |
Poppy | 1/0 | 53.48 | 7/3.119 | 147 | 9.36 | 873 | 0.5390 |
Aster | 2/0 | 67.42 | 7/3.503 | 186 | 10.51 | 1100 | 0.4276 |
Phlox | 3/0 | 85.03 | 7/3.932 | 234 | 11.80 | 1347 | 0.3390 |
Oxlip | 4/0 | 107.23 | 7/4.417 | 296 | 13.26 | 1698 | 0.2688 |
Valerian | 250 | 126.71 | 19/2.931 | 349 | 14.57 | 2062 | 0.2275 |
Sneezewort | 250 | 126.71 | 7/4.80 | 349 | 14.4 | 2007 | 0.2275 |
Laurel | 266.8 | 135.16 | 19/3.01 | 373 | 15.05 | 2200 | 0.2133 |
Daisy | 266.8 | 135.16 | 7/4.96 | 373 | 14.9 | 2141 | 0.2133 |
Peony | 300 | 152.0 | 19/3.193 | 419 | 15.97 | 2403 | 0.1896 |
Tulip | 336.4 | 170.45 | 19/3.381 | 470 | 16.91 | 2695 | 0.1691 |
Daffodil | 350 | 177.35 | 19/3.447 | 489 | 17.24 | 2804 | 0.1625 |
Canna | 397.5 | 201.42 | 19/3.673 | 555 | 18.36 | 3184 | 0.1431 |
Goldentuft | 450 | 228 | 19/3.909 | 629 | 19.55 | 3499 | 0.1264 |
Syringa | 477 | 241.68 | 37/2.882 | 666 | 20.19 | 3849 | 0.1193 |
Cosmos | 477 | 241.68 | 19/4.023 | 666 | 20.12 | 3708 | 0.1193 |
Hyacinth | 500 | 253.35 | 37/2.951 | 698 | 20.65 | 4035 | 0.1138 |
Zinnia | 500 | 253.35 | 19/4.12 | 698 | 20.6 | 3888 | 0.1138 |
Dahlia | 556.5 | 282 | 19/4.346 | 777 | 21.73 | 4327 | 0.1022 |
Mistletoe | 556.5 | 282 | 37/3.114 | 777 | 21.79 | 4362 | 0.1022 |
Meadowsweet | 600 | 304 | 37/3.233 | 838 | 22.63 | 4703 | 0.0948 |
Orchid | 636 | 322.25 | 37/3.33 | 888 | 23.31 | 4985 | 0.0894 |
Heuchera | 650 | 329.35 | 37/3.366 | 908 | 23.56 | 5095 | 0.0875 |
Flag | 700 | 354.71 | 61/2.72 | 978 | 24.48 | 5146 | 0.0813 |
AAC conductor Standard: ASTM B231
Code Name | Total Area | Stranding and wire diameter mm | Overall Diameter mm | Linear Mass kg/mass | Nominal Breaking Load daN | Max. D.C. Resistance at 20℃ ≤Ω/km | |
AWG or MCM | mm2 | ||||||
Verbena | 700 | 354.71 | 37/3.493 | 24.45 | 978 | 5487 | 0.0813 |
Nasturtium | 715.5 | 362.58 | 61/2.75 | 24.76 | 1000 | 5874 | 0.0795 |
Violet | 715.5 | 362.58 | 37/3.533 | 24.74 | 1000 | 5609 | 0.0795 |
Cattail | 750 | 380 | 61/2.817 | 25.35 | 1048 | 5985 | 0.0759 |
Petunia | 750 | 380 | 37/3.617 | 25.32 | 1048 | 5875 | 0.0759 |
Lilac | 795 | 402.84 | 61/2.90 | 26.11 | 1111 | 6345 | 0.0715 |
Arbutus | 795 | 402.84 | 37/3.724 | 26.06 | 1111 | 6232 | 0.0715 |
Snapdragon | 900 | 456.06 | 61/3.086 | 27.78 | 1257 | 6978 | 0.0632 |
Cockscomb | 900 | 456.06 | 37/3.962 | 27.73 | 1257 | 6848 | 0.0632 |
Goldenrod | 954 | 483.42 | 61/3.177 | 28.6 | 1333 | 7896 | 0.0596 |
Magnolia | 954 | 483.42 | 37/4.079 | 28.55 | 1333 | 7258 | 0.0596 |
Camellia | 1000 | 506.71 | 61/3.251 | 29.36 | 1397 | 7753 | 0.0569 |
Hawkweed | 1000 | 506.71 | 37/4.176 | 29.23 | 1397 | 7608 | 0.0569 |
Larkspur | 1033.5 | 523.68 | 61/3.307 | 29.76 | 1444 | 8012 | 0.0550 |
Bluebell | 1033.5 | 523.68 | 37/4.244 | 29.72 | 1444 | 7863 | 0.0550 |
Marigold | 1113 | 563.93 | 61/3.432 | 30.89 | 1555 | 8628 | 0.0511 |
Hawthorn | 1192.5 | 604.26 | 61/3.551 | 31.05 | 1666 | 9245 | 0.0477 |
Narcissus | 1272 | 644.51 | 61/3.668 | 33.02 | 1777 | 9861 | 0.0477 |
Columbine | 1351.5 | 684.84 | 61/3.78 | 34.01 | 1888 | 10478 | 0.0421 |
Carnation | 1431 | 725.10 | 61/3.89 | 35.03 | 1999 | 10768 | 0.0398 |
Gladiolus | 1510.5 | 765.35 | 61/4.00 | 35.09 | 2110 | 11365 | 0.0376 |
Coreopsis | 1590 | 805.68 | 61/4.099 | 36.51 | 2221 | 11964 | 0.0358 |
Jessamine | 1750 | 886.71 | 61/4.302 | 38.72 | 2445 | 13168 | 0.0325 |
Cowslip | 2000 | 1013.42 | 91/3.76 | 41.40 | 2791 | 15300 | 0.0285 |
Lupine | 2500 | 1266.67 | 91/4.21 | 46.30 | 3524 | 18700 | 0.0230 |
Trillium | 3000 | 1520.13 | 127/3.90 | 50.75 | 4232 | 22500 | 0.0192 |
Bluebonnet | 3500 | 1773.50 | 127/4.21 | 54.80 | 4985 | 26200 | 0.0166 |
AAC Standard: BS215 Part 1
Nominal Alum Area mm2 | Stranding and wire diameter mm | Sectional Area mm2 | Approx. Weight Kg/km | Overall Diameter mm | Max..D.C. Resistance At 20℃ ≤Ω/km | Calculated breaking load da N | Final Modulus Of Elasticity hbar | Coefficient of Linear Expansion /℃ |
22 | 7/2.06 | 23.33 | 64 | 6.18 | 1.227 | 399 | 5900 | 23×10﹣⒍ |
25 | 3/3.35 | 26.40 | 73 | 7.2 | 1.081 | 411 | 5900 | 23×10﹣⒍ |
25 | 7/2.21 | 26.8 | 73 | 6.6 | 1.066 | 459 | 5900 | 23×10﹣⒍ |
30 | 3/3.66 | 31.6 | 86 | 7.9 | 0.9082 | 486 | 5900 | 23×10﹣⒍ |
35 | 7/2.59 | 37.0 | 101 | 7.8 | 0.7762 | 603 | 5900 | 23×10﹣⒍ |
40 | 7/2.79 | 42.8 | 117 | 8.4 | 0.6689 | 687 | 5900 | 23×10﹣⒍ |
50 | 7/3.10 | 52.83 | 145 | 9.30 | 0.5419 | 828 | 5900 | 23×10﹣⒍ |
60 | 7/3.40 | 63.55 | 174 | 10.20 | 0.4505 | 990 | 5900 | 23×10﹣⒍ |
70 | 7/3.66 | 73.7 | 202 | 11.0 | 0.3881 | 1134 | 5900 | 23×10﹣⒍ |
75 | 7/3.78 | 78.5 | 215 | 11.4 | 0.3644 | 1194 | 5900 | 23×10﹣⒍ |
80 | 7/3.91 | 84.1 | 230 | 11.7 | 0.3406 | 1278 | 5900 | 23×10﹣⒍ |
90 | 7/4.17 | 95.6 | 262 | 12.5 | 0.2994 | 1453 | 5900 | 23×10﹣⒍ |
100 | 7/4.39 | 106.0 | 290 | 13.17 | 0.2702 | 1600 | 5900 | 23×10﹣⒍ |
100 | 19/2.67 | 106.0 | 293 | 13.4 | 0.2704 | 1742 | 5600 | 23×10﹣⒍ |
125 | 7/4.90 | 132.0 | 361 | 14.7 | 0.2169 | 1944 | 5900 | 23×10﹣⒍ |
150 | 7/5.36 | 157.9 | 432 | 16.1 | 0.1818 | 2385 | 5900 | 23×10﹣⒍ |
150 | 19/3.25 | 157.9 | 434 | 16.25 | 0.1825 | 2570 | 5600 | 23×10﹣⒍ |
175 | 19/3.53 | 186 | 512 | 17.7 | 0.1547 | 2863 | 5600 | 23×10﹣⒍ |
200 | 19/3.78 | 213.2 | 587 | 18.9 | 0.1349 | 3240 | 5600 | 23×10﹣⒍ |
225 | 19/3.99 | 236.9 | 652 | 20.0 | 0.1211 | 3601 | 5600 | 23×10﹣⒍ |
250 | 19/4.22 | 265.7 | 731 | 21.10 | 0.1083 | 4040 | 5600 | 23×10﹣⒍ |
300 | 19/4.65 | 322.7 | 888 | 23.25 | 0.08916 | 4875 | 5600 | 23×10﹣⒍ |
350 | 37/5.00 | 373.2 | 1027 | 25.0 | 0.07711 | 5637 | 5600 | 23×10﹣⒍ |
350 | 19/3.58 | 373.3 | 1029 | 25.1 | 0.07741 | 5745 | 5600 | 23×10﹣⒍ |
400 | 37/5.36 | 428.5 | 1179 | 26.8 | 0.06710 | 6473 | 5600 | 23×10﹣⒍ |
400 | 37/3.78 | 415.2 | 1145 | 26.46 | 0.06944 | 6310 | 5600 | 23×10﹣⒍ |
450 | 37/4.09 | 486.9 | 1342 | 28.6 | 0.05931 | 7401 | 5600 | 23×10﹣⒍ |
500 | 37/4.27 | 529.5 | 1460 | 29.9 | 0.05441 | 7998 | 5600 | 23×10﹣⒍ |
600 | 37/4.65 | 628.6 | 1733 | 32.6 | 0.04588 | 9495 | 5600 | 23×10﹣⒍ |
750 | 37/5.23 | 794.6 | 2191 | 36.6 | 0.03627 | 12010 | 5600 | 23×10﹣⒍ |
AAC conductor Standard: DIN 48201
Nominal Alum mm2 | Calculated Area mm2 | Stranding and wire diameter mm | Overall Diameter mm | Max.D.C. Resistance At 20℃ ≤Ω/km | Calculated breaking load daN | Approx. Weight kg/km |
16 | 15.89 | 7/1.70 | 5.1 | 1.8018 | 290 | 44 |
25 | 24.25 | 7/2.10 | 6.3 | 1.1808 | 425 | 67 |
35 | 34.36 | 7/2.50 | 7.5 | 0.8332 | 585 | 94 |
50 | 49.48 | 7/3.00 | 9.0 | 0.5786 | 810 | 135 |
50 | 48.36 | 19/1.80 | 9.0 | 0.5950 | 860 | 133 |
70 | 65.82 | 19/2.10 | 10.5 | 0.4371 | 1150 | 181 |
95 | 93.27 | 19/2.50 | 12.5 | 0.3084 | 1595 | 256 |
120 | 117.00 | 19/2.80 | 14.0 | 0.2459 | 1910 | 322 |
150 | 147.10 | 37/2.25 | 15.2 | 0.1960 | 2570 | 406 |
185 | 181.60 | 37/2.50 | 17.5 | 0.1587 | 3105 | 501 |
240 | 242.54 | 61/2.25 | 20.2 | 0.1191 | 4015 | 670 |
300 | 299.43 | 61/2.50 | 22.5 | 0.09650 | 4850 | 827 |
400 | 400.14 | 61/2.89 | 26.0 | 0.07221 | 6190 | 1105 |
500 | 499.83 | 61/3.23 | 29.1 | 0.05781 | 7600 | 1381 |
625 | 626.20 | 91/2.96 | 32.6 | 0.04625 | 9690 | 1733 |
800 | 802.10 | 91/3.35 | 36.8 | 0.03611 | 12055 | 2219 |
1000 | 999.71 | 91/3.74 | 41.1 | 0.02897 | 14845 | 2766 |


Our Bare Stranded Overhead Power Transmission Line AAC/AAAC/ACSR Conductor are of first-class quality and provide first-class after-sales service. We hope to guarantee and intellectually support with solid talents, thus shaping a high-quality talent team. We have a sense of social responsibility, abide by the law and discipline, protect the environment, and pursue the harmony between enterprise growth and social development.
Hot Tags: aac conductor, China, suppliers, manufacturers, factory, wholesale, price, in stock, price list, made in China, Electric Cable, TSJ cable, Flexible Trailing Cable, Flexible PUR Spiral Cable, Building Wire, High Voltage XLPE Cable