Faced with economic globalization, we are determined to become a leader in the Teflon Insulated Wire, PVC Insulation Building Wire Cable, Cat6 Cable industry and surpass ourselves. We sincerely hope to cooperate with you, share success together, and forge ahead firmly to a more brilliant future. We firmly believe that an enterprise that strives for excellence in quality and is honest and pragmatic to customers will eventually become a leader in the industry. The company actively cooperates with the national development policy of industry-university-research cooperation, and has established close cooperative relations with first-class universities at home and abroad. We use our long-accumulated technology and experience to further optimize the allocation of resources.
AAAC Aaac Conductor -All Aluminum Alloy Conductor
1.Bare AAAC conductor is usually used for power transmission line project.
2.We are familiar with different international standards with IEC,BS,DIN, ASTM.We an supply very professional service for customer.
3.Packing: in drums in 2000m or 3000m according to customer’s requirement
4.Delivery: about 50km production per day
AAAC Conductor (JLHA1)
Standard: Chinese Standard GB/T 1179-2008
Nominal Aera mm2 | Code Number | Calculated Area mm2 | Number of Wires | Diameter | Rated Strength KN | Max. D.C. Resistance at 20℃ ≤Ω/km | |
Wire mm | OD mm | ||||||
20 | 16 | 18.6 | 7 | 1.84 | 5.52 | 6.04 | 1.7896 |
30 | 25 | 29.0 | 7 | 2.30 | 6.90 | 9.44 | 1.1453 |
45 | 40 | 46.5 | 7 | 2.91 | 8.72 | 15.10 | 0.7158 |
75 | 63 | 73.2 | 7 | 3.65 | 10.9 | 23.06 | 0.4545 |
120 | 100 | 116 | 19 | 2.79 | 14.0 | 37.76 | 0.2877 |
145 | 125 | 145 | 19 | 3.12 | 15.6 | 47.20 | 0.2302 |
185 | 160 | 186 | 19 | 3.53 | 17.6 | 58.56 | 0.1798 |
230 | 200 | 232 | 19 | 3.95 | 19.7 | 73.20 | 0.1439 |
300 | 250 | 290 | 19 | 4.41 | 22.1 | 91.50 | 0.1151 |
360 | 315 | 366 | 37 | 3.55 | 24.8 | 115.29 | 0.0916 |
465 | 400 | 465 | 37 | 4.00 | 28.0 | 146.40 | 0.0721 |
520 | 450 | 523 | 37 | 4.24 | 29.7 | 164.70 | 0.0641 |
580 | 500 | 581 | 37 | 4.47 | 31.3 | 183.00 | 0.0577 |
650 | 560 | 651 | 61 | 3.69 | 33.2 | 204.96 | 0.0516 |
720 | 630 | 732 | 61 | 3.91 | 35.2 | 230.58 | 0.0458 |
825 | 710 | 825 | 61 | 4.15 | 37.3 | 259.86 | 0.0407 |
930 | 800 | 930 | 61 | 4.40 | 39.6 | 292.80 | 0.0361 |
1050 | 900 | 1046 | 91 | 3.83 | 42.1 | 329.40 | 0.0321 |
1150 | 1000 | 1162 | 91 | 4.03 | 44.4 | 366.00 | 0.0289 |
1300 | 1120 | 1301 | 91 | 4.27 | 46.9 | 409.92 | 0.0258 |
AAAC Conductor
Standard: ASTM B399
Code name | Area | No./wire diameter | Overall diameter | Weight | Nominal breaking load | Standard length | |
Nominal | Actual | ||||||
MCM | mm2 | mm | mm | Kg/km | KN | m±5% | |
Akron | 30.58 | 15.48 | 7/1.68 | 5.04 | 42.7 | 4.92 | 3000 |
Alton | 48.69 | 24.71 | 7/2.12 | 6.35 | 68.0 | 7.84 | 3000 |
Ames | 77.47 | 39.22 | 7/2.67 | 8.02 | 108 | 12.45 | 2000 |
Azusa | 123.3 | 62.38 | 7/3.37 | 10.11 | 172 | 18.97 | 2000 |
Anaheim | 155.4 | 78.65 | 7/3.78 | 11.35 | 217 | 23.93 | 3000 |
Amherst | 195.7 | 99.22 | 7/4.25 | 12.75 | 273 | 30.18 | 2500 |
Alliance | 246.9 | 125.1 | 7/4.77 | 14.31 | 345 | 38.05 | 2000 |
Butte | 312.8 | 158.6 | 19/3.26 | 16.30 | 437 | 48.76 | 3000 |
Canton | 394.5 | 199.9 | 19/3.66 | 18.30 | 551 | 58.91 | 2500 |
Cairo | 465.4 | 235.8 | 19/3.98 | 19.88 | 650 | 69.48 | 2000 |
Darien | 559.5 | 283.5 | 19/4.36 | 21.79 | 781 | 83.52 | 2000 |
Elgin | 652.4 | 330.6 | 19/4.71 | 23.54 | 911 | 97.42 | 1500 |
Flint | 740.8 | 375.3 | 37/3.59 | 25.16 | 1035 | 108.21 | 3000 |
Greely | 927.2 | 469.8 | 37/4.02 | 28.14 | 1295 | 135.47 | 2500 |
AAAC conductor
Standard: ASTM B399
Area | No./wire diameter | Overall diameter | Weight | Nominal breaking load | Max D.C. resistance at 20℃ | Standard length | |
Nominal | Actual | ||||||
AWG or MCM | mm2 | mm | mm | Kg/km | KN | Ω/km | m±5% |
6 | 13.30 | 7/1.554 | 4.67 | 37 | 4.22 | 2.5199 | 3500 |
4 | 21.15 | 7/1.961 | 5.89 | 58 | 6.71 | 1.5824 | 3000 |
2 | 33.63 | 7/2.474 | 7.42 | 93 | 10.68 | 0.9942 | 2500 |
1/0 | 53.48 | 7/3.119 | 9.36 | 148 | 16.97 | 0.6256 | 2000 |
2/0 | 67.42 | 7/3.503 | 10.51 | 186 | 20.52 | 0.4959 | 3500 |
3/0 | 85.03 | 7/3.932 | 11.80 | 234 | 25.86 | 0.3939 | 3000 |
4/0 | 107.23 | 7/4.417 | 13.26 | 296 | 32.63 | 0.3119 | 2000 |
250 | 126.66 | 19/2.913 | 14.57 | 349 | 38.93 | 0.2642 | 2000 |
300 | 152.10 | 19/3.193 | 15.97 | 419 | 46.77 | 0.2199 | 3000 |
350 | 177.35 | 19/3.447 | 17.24 | 489 | 52.25 | 0.1887 | 3000 |
400 | 202.71 | 19/3.686 | 18.43 | 559 | 59.74 | 0.1650 | 2500 |
450 | 228.00 | 19/3.909 | 19.66 | 629 | 67.19 | 0.1467 | 2000 |
500 | 253.35 | 19/4.120 | 20.60 | 698 | 74.64 | 0.1321 | 2000 |
550 | 278.60 | 37/3.096 | 21.67 | 768 | 83.80 | 0.1202 | 2000 |
600 | 303.80 | 37/3.233 | 22.63 | 838 | 91.38 | 0.1102 | 2000 |
650 | 329.25 | 37/3.366 | 23.56 | 908 | 97.94 | 0.1016 | 2000 |
700 | 354.55 | 37/3.493 | 24.45 | 978 | 102.20 | 0.0944 | 3500 |
750 | 380.20 | 37/3.617 | 25.32 | 1049 | 109.60 | 0.0880 | 3000 |
800 | 405.15 | 37/3.734 | 26.14 | 1117 | 116.80 | 0.0826 | 3000 |
900 | 456.16 | 37/3.962 | 27.73 | 1258 | 131.50 | 0.0733 | 3000 |
1000 | 506.71 | 37/4.176 | 29.23 | 1399 | 146.10 | 0.0660 | 2500 |
AAAC Conductor Cable
Standard: BS EN50183
Code name | Calculated area | No of wires | Diameter | Weight | Rated strength | Max D.C. resistance at 20℃ | |
Wire | Cond | ||||||
mm2 | mm | mm | Kg/km | KN | Ω/km | ||
Box | 18.8 | 7 | 1.85 | 5.55 | 51.4 | 5.55 | 1.7480 |
Acacia | 23.8 | 7 | 2.08 | 6.24 | 64.9 | 7.02 | 1.3828 |
Almond | 30.1 | 7 | 2.34 | 7.02 | 82.2 | 8.88 | 1.0926 |
Cedar | 35.5 | 7 | 2.54 | 7.62 | 96.8 | 10.46 | 0.9273 |
Deodar | 42.2 | 7 | 2.77 | 8.31 | 115.2 | 12.44 | 0.7797 |
Fir | 47.8 | 7 | 2.95 | 8.85 | 130.6 | 14.11 | 0.6875 |
Hazel | 59.9 | 7 | 3.30 | 9.90 | 163.4 | 17.66 | 0.5494 |
Pine | 71.6 | 7 | 3.61 | 10.8 | 195.6 | 21.14 | 0.4591 |
Holly | 84.1 | 7 | 3.91 | 11.7 | 229.5 | 24.79 | 0.3913 |
Willow | 89.7 | 7 | 4.04 | 12.1 | 245.0 | 26.47 | 0.3665 |
Oak | 118.9 | 7 | 4.65 | 14.0 | 324.5 | 65.07 | 0.2767 |
Mulberry | 150.9 | 19 | 3.18 | 15.9 | 414.3 | 44.52 | 0.2192 |
Ash | 180.7 | 19 | 3.48 | 17.4 | 496.1 | 53.31 | 0.1830 |
Elm | 211.0 | 19 | 3.76 | 18.8 | 579.2 | 62.24 | 0.1568 |
Poplar | 239.4 | 37 | 2.87 | 20.1 | 659.4 | 70.61 | 0.1387 |
Sycamore | 303.2 | 37 | 3.23 | 22.6 | 835.2 | 89.40 | 0.1095 |
Upas | 362.1 | 37 | 3.53 | 24.7 | 997.5 | 106.82 | 0.0917 |
Yew | 479.0 | 37 | 4.06 | 28.4 | 1319.6 | 141.31 | 0.0693 |
Totara | 498.1 | 37 | 4.14 | 29.0 | 1372.1 | 145.93 | 0.0666 |
Rubus | 586.9 | 61 | 3.50 | 31.5 | 1622.0 | 173.13 | 0.0567 |
Sorbus | 659.4 | 61 | 3.71 | 33.4 | 1822.5 | 194.53 | 0.0505 |
Araucaria | 821.1 | 61 | 4.14 | 37.3 | 2269.4 | 242.24 | 0.0406 |
Redwood | 996.2 | 61 | 4.56 | 41.0 | 2753.2 | 293.88 | 0.0334 |
AAAC
Standard: BS 3242
Code name | Nominal area | No of wires | Diameter | Weight | Rated strength | Max D.C. resistance at 20℃ | |
Wire | Cond | ||||||
mm2 | mm | mm | Kg/km | KN | Ω/km | ||
Box | 15 | 7 | 1.85 | 5.55 | 51 | 5.37 | 1.7495 |
Acacia | 20 | 7 | 2.08 | 6.24 | 65 | 6.80 | 1.3840 |
Almond | 25 | 7 | 2.34 | 7.02 | 82 | 8.61 | 1.0934 |
Cedar | 30 | 7 | 2.54 | 7.62 | 97 | 10.14 | 0.9281 |
- | 35 | 7 | 2.77 | 8.31 | 115 | 12.05 | 0.7804 |
Fir | 40 | 7 | 2.95 | 8.85 | 131 | 13.67 | 0.6880 |
Hazel | 50 | 7 | 3.30 | 9.90 | 164 | 17.11 | 0.5498 |
Pine | 60 | 7 | 3.61 | 10.83 | 196 | 20.48 | 0.4594 |
- | 70 | 7 | 3.91 | 11.73 | 230 | 24.02 | 0.3917 |
Willow | 75 | 7 | 4.04 | 12.12 | 245 | 25.65 | 0.3669 |
- | 80 | 7 | 4.19 | 12.57 | 264 | 27.58 | 0..3441 |
- | 90 | 7 | 4.44 | 13.32 | 298 | 31.12 | 0.3023 |
Oak | 100 | 7 | 4.65 | 13.95 | 325 | 33.98 | 0.2769 |
- | 100 | 19 | 2.82 | 14.1 | 326 | 33.93 | 0.2787 |
Mulberry | 125 | 19 | 3.18 | 15.9 | 415 | 43.12 | 0.2192 |
Ash | 150 | 19 | 3.48 | 17.4 | 497 | 51.64 | 0.1831 |
Elm | 175 | 19 | 3.76 | 18.8 | 580 | 60.30 | 0.1568 |
Poplar | 200 | 37 | 2.87 | 20.09 | 659 | 88.41 | 0.1385 |
- | 225 | 37 | 3.05 | 21.35 | 744 | 77.24 | 0.1227 |
Sycamore | 250 | 37 | 3.22 | 22.54 | 835 | 86.64 | 0.1093 |
Upas | 300 | 37 | 3.53 | 24.71 | 997 | 103.50 | 0.09156 |
Walnut | 350 | 37 | 3.81 | 26.67 | 1162 | 120.53 | 0.07860 |
Yew | 400 | 37 | 4.06 | 28.42 | 1319 | 136.85 | 0.06921 |
Totara | 425 | 37 | 4.14 | 28.98 | 1372 | 142.33 | 0.06656 |
Rubus | 500 | 61 | 3.50 | 31.5 | 1620 | 167.71 | 0.05662 |
Sorbus | 659.4 | 61 | 3.71 | 33.4 | 1822.5 | 194.53 | 0.0505 |
Araucaria | 700 | 61 | 4.14 | 37.26 | 2266 | 234.50 | 0.04047 |
AAAC
Standard: DIN 48201
Code number | Calculated area | No of wires | Diameter | Weight | Rated tensile strength | Max D.C. resistance at 20℃ | |
Wire | Cond | ||||||
mm2 | mm2 | mm | mm | Kg/km | daN | Ω/km | |
16 | 15.89 | 7 | 1.70 | 5.1 | 43 | 444 | 2.0910 |
25 | 24.25 | 7 | 2.10 | 6.3 | 66 | 677 | 1.3703 |
35 | 34.36 | 7 | 2.50 | 7.5 | 94 | 960 | 0.9669 |
50 | 49.48 | 7 | 3.00 | 9.0 | 135 | 1382 | 0.6714 |
50 | 48.35 | 19 | 1.80 | 9.0 | 133 | 1350 | 0.6905 |
70 | 65.81 | 19 | 2.10 | 10.5 | 181 | 1838 | 0.5073 |
95 | 93.27 | 19 | 2.50 | 12.5 | 256 | 2605 | 0.3579 |
120 | 116.99 | 19 | 2.80 | 14.0 | 322 | 3268 | 0.2854 |
150 | 147.11 | 37 | 2.25 | 15.8 | 406 | 4109 | 0.2274 |
185 | 181.62 | 37 | 2.50 | 17.5 | 500 | 5073 | 0.1842 |
240 | 242.54 | 61 | 2.25 | 20.3 | 670 | 6774 | 0.1383 |
300 | 299.43 | 61 | 2.50 | 22.5 | 827 | 8363 | 0.1120 |
400 | 400.14 | 61 | 2.89 | 26.0 | 1104 | 11176 | 0.0838 |
500 | 499.63 | 61 | 3.23 | 29.1 | 1379 | 13960 | 0.06709 |
625 | 626.20 | 91 | 2.96 | 32.6 | 1732 | 17490 | 0.0540 |
800 | 802.09 | 91 | 3.35 | 36.9 | 2218 | 22402 | 0.0418 |
1000 | 999.71 | 91 | 3.74 | 41.1 | 2767 | 27922 | 0.0335 |
AAAC(Characteristics of A2 Conductors)
Standard: IEC 61089
Code Number | Calculated Area | Number of Wires | Diameter of Wire | Diameter of Cond. | Linear Mass | Rated Strength | Max.D.C. Resistance At 20℃ |
mm2 | mm2 | mm | mm | kg/km | kN | Ω/km | |
16 | 18.4 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 1.7896 |
25 | 28.8 | 7 | 2.29 | 6.87 | 78.7 | 8.49 | 1.1453 |
40 | 46.0 | 7 | 2.89 | 8.67 | 125.9 | 13.58 | 0.7158 |
63 | 72.5 | 7 | 3.63 | 10.8 | 198.3 | 21.39 | 0.4545 |
100 | 115 | 19 | 2.78 | 13.9 | 316.3 | 33.95 | 0.2877 |
125 | 144 | 19 | 3.10 | 15.5 | 395.4 | 42.44 | 0.2302 |
160 | 184 | 19 | 3.51 | 17.55 | 506.1 | 54.32 | 0.1798 |
200 | 230 | 19 | 3.93 | 19.65 | 632.7 | 67.91 | 0.1439 |
250 | 288 | 19 | 4.39 | 21.95 | 790.8 | 84.68 | 0.1151 |
315 | 363 | 37 | 3.53 | 24.71 | 998.9 | 106.95 | 0.0916 |
400 | 460 | 37 | 3.98 | 27.86 | 1268.4 | 135.81 | 0.0721 |
450 | 518 | 37 | 4.22 | 29.54 | 1426.9 | 152.79 | 0.0641 |
500 | 575 | 37 | 4.45 | 31.15 | 1585.5 | 169.76 | 0.0577 |
560 | 645 | 61 | 3.67 | 33.03 | 1778.4 | 190.14 | 0.0516 |
630 | 725 | 61 | 3.89 | 35.01 | 2000.7 | 213.90 | 0.0458 |
710 | 817 | 61 | 4.13 | 37.17 | 2254.8 | 241.07 | 0.0407 |
800 | 921 | 61 | 4.38 | 39.42 | 2540.6 | 271.62 | 0.0361 |
900 | 1036 | 91 | 3.81 | 41.91 | 2861.1 | 305.58 | 0.0632 |
1000 | 1151 | 91 | 4.01 | 44.11 | 3179.0 | 339.53 | 0.0289 |
1120 | 1289 | 91 | 4.25 | 46.75 | 3560.5 | 380.27 | 0.0258 |
1252 | 1439 | 91 | 4.49 | 49.39 | 3973.7 | 424.41 | 0.0231 |
AAAC(Characteristics of A3 Conductors)
Standard : IEC 61089
Code Number | Calculated Area | Number of Wires | Diameter of Wire | Diameter of Cond. | Linear Mass | Rated Strength | Max.D.C. Resistance At 20℃ |
mm2 | mm2 | mm | mm | kg/km | kN | Ω/km | |
16 | 18.6 | 7 | 1.84 | 5.52 | 50.8 | 6.04 | 1.7896 |
25 | 29.0 | 7 | 2.30 | 6.90 | 79.5 | 9.44 | 1.1453 |
40 | 46.5 | 7 | 2.91 | 8.73 | 127.1 | 15.10 | 0.7158 |
63 | 73.2 | 7 | 3.65 | 10.95 | 200.2 | 23.06 | 0.4545 |
100 | 116 | 19 | 2.79 | 13.95 | 319.3 | 37.76 | 0.2877 |
125 | 145 | 19 | 3.12 | 15.6 | 399.2 | 47.20 | 0.2302 |
160 | 186 | 19 | 3.53 | 17.65 | 511.0 | 58.56 | 0.1798 |
200 | 232 | 19 | 3.95 | 19.75 | 638.7 | 73.20 | 0.1439 |
250 | 290 | 19 | 4.41 | 22.05 | 798.4 | 91.50 | 0.1151 |
315 | 366 | 37 | 3.55 | 24.85 | 1008.4 | 115.29 | 0.0916 |
400 | 465 | 37 | 4.00 | 28.0 | 1280.5 | 146.40 | 0.0721 |
450 | 523 | 37 | 4.24 | 29.68 | 1440.5 | 164.70 | 0.0641 |
500 | 581 | 37 | 4.47 | 31.29 | 1600.6 | 183.00 | 0.0577 |
560 | 651 | 61 | 3.69 | 33.21 | 1795.3 | 204.95 | 0.0516 |
630 | 732 | 61 | 3.91 | 35.19 | 2019.8 | 230.58 | 0.0458 |
710 | 825 | 61 | 4.15 | 37.35 | 2276.2 | 259.86 | 0.0407 |
800 | 930 | 61 | 4.40 | 39.6 | 2564.8 | 292.80 | 0.0361 |
900 | 1046 | 91 | 3.83 | 42.13 | 2888.3 | 329.40 | 0.0321 |
1000 | 1162 | 91 | 4.03 | 44.33 | 3209.3 | 366.00 | 0.0289 |
1120 | 1301 | 91 | 4.27 | 46.97 | 3594.4 | 409.92 | 0.0258 |

Our firm aims to operating faithfully, serving to all of our shoppers, and working in new technology and new machine consistently for Bare Aluminium Conductor Steel Reinforced AAC/AAAC/ACSR Conductor. Quality is the bridge between us and customers, and integrity is the foundation of our guarantee to customers. We constantly innovate and improves product system and serve customers with cutting-edge technology and excellent quality.